High Accuracy Insertion Magnetic Flow Meter For Big Diameter Pipeline
Negotiable /Set
Min.Order:1 Set
Nanjing Metlan Measurement & Control Instrument Co., Ltd
High Performance Precision Flow Meter Turbine Type With SS304 Material
Thread Type Good Repeatability Turbine Flow Meter For Chemical Industry
Tri-Clover Type Small Diameter Turbine Water Flow Meter Easy Installation
Remote Type Liquid Electromagnetic Flow Meter with RS485 / HART
220V Liquid / Solid Magnetic Type Flow Meter Abrasion Resistance
SS304 High Temperature Intelligent Vortex Flow Meter Anti Interference
High Accuracy Insertion Magnetic Flow Meter For Big Diameter Pipeline
Technical Parameters
Measuring medium: Steam,gas, liquid
Accuracy:Liquid:1.0% Gas:1.5%
Repeatability:Liquid 0.33% Gas:0.5%
Range:Liquid:0.7m/s~7m/s Gas:7m/s~40m/s
Working pressure:Standard 1.6MPa,2.5~4.0 MPa (on request)
Fluid temperature:-40℃~250℃(Common type);100℃~
350℃(High-temperature type)
Body material:304 stainless steel(SS316 is optional)
Output signal:Pulse(three wires,low level≤1V;High level≧4V);
4~20mA;RS485
Power supply:24VDC(12VDC),Lithium battery
Ambient temperature : -35 ℃ ~ 60 ℃ ( without LCD );
-5℃~60℃(with LCD)
Relative humidity:5~95%
Protection level:IP65
Electrical connection:M20*1.5
Explosion-proof::Optional
●The structure of Vortex flow meter is simple and strong, no
movable parts,and it is very stable.
●Simple installation and easy maintenance
●Wide measuring rang,the ratio is up to 10:1.
●Low pressure loss and operating costs.
●When measuring the volume of fluid,compensate as
required,replace parts without re-calibrate the flow meter.
Application:
LUGB series Vortex Flowmeter sensor can be used to detect and measure the flow of all kinds of
gas, fluid and steam.
LUGB flowmeter sensor can be used to match with our company’s MT6000 series flow totalizer. It also
can match with computers and sensors of temperature, pressure, or density to compose highaccuracy
mass flow or heat flow detecting and measuring system.
Features:
1) Measuring medium: Steam,gas, liquid(Avoid of multiple- direction fluid)
2) Accuracy:Liquid:1.0% Gas:1.5%
3) Repeatability:Liquid 0.33% Gas:0.5%
4) Range:Liquid:0.7m/s~7m/s Gas:7m/s~40m/s
5) Working pressure:Standard 1.6MPa,2.5~4.0 MPa (on request)
6) Fluid temperature:-40℃~250℃(Common type);100℃~350℃(High-temperature type)
7) Body material:304 stainless steel(SS316 is optional)
8) Output signal:Pulse(three wires,low level≤1V;High level≧4V);4~20mA;RS485
9) Power supply:24VDC(12VDC),Lithium battery
10) Ambient temperature : -35 ℃ ~ 60 ℃ ( without LCD ); -5℃~60℃(with LCD)
11) Relative humidity:5~95%
12) Protection level:IP65
13) Electrical connection:M20*1.5
14) Explosion-proof:Optional
15) The structure of Vortex flow meter is simple and strong, no movable parts,and it is very stable.
16) Simple installation and easy maintenance
Data sheet
Customer Order Information Table