Electronic Submersible Level Transmitter Electromagnetic Flowmeters
Negotiable /Piece
Min.Order:1 Piece
Nanjing Metlan Measurement & Control Instrument Co., Ltd
Digital Industrial Liquid Electromagnetic Flow Meter 12V Battery Power
Battery Powered Submersible Flow Meter With GB4208-84 IEC Standard
Outdoor Waterproof Electromagnetic Flow Meter , Chemical Flowmeter
316L Smart Electromagnetic Flow Transmitter With Carbon Flange
50mm Acid Electromagnetic Flow Meter High Accurancy for City Administration
High Stability Electromagnetic Type Flow Meters For Water Self Diagnosis
Electronic Submersible Level Transmitter Electromagnetic Flowmeters
Performance indexes
■ Ambient temperature-20℃―50℃
■ Ambient humidity≦95%
■ Level of protection for case: IP68
■ Measuring range of flow rate:0 --- 15m/s
■ Medium conductivity: clean water > 20 μs/cm
■ Range of nominal diameters measurableDN10—DN800
■ Accuracy grade of sensors: Grade 0.5, grade 0.2
■ Measurable parameters: instantaneous flow rate, instantaneous flow velocity
■ Recordable parameters: accumulative total of flow, record of 32 events
Test alarm parameters: Fluid empty-tube test alarm
Exciting current test alarm
Battery capacity test alarm
■ Calibrated output signal: Flow and impulse per unit volume
■ Radio communication mode: SRD,GPRS,CDMA
Summary
Developed by my company, W802 series electromagnetic water meter
converters are battery powered, capable of being used together with common
electromagnetic flow meters, with the flow rate measurement accuracy up to 0.5
level and 0.2 level. That is to say, a new type of products — electromagnetic
water meter series will be developed simply by connecting a W802
convertor to a common electromagnetic flow meter.
▲ For 20mA excitation, resistance of excitation coil of sensor: 90~110 ohm (two in series)
(it is suggested)
▲ For 50mA excitation, resistance of excitation coil of sensor: 40~50 ohm (two in series)
▲ Signal intensity of flow of sensor: 50~100μv (1m/s flow rate)
Note:
It must be particularly stated for the parameters of excitation coil resistance when
placing an order!
Instructions:
When calibrating flow, if the sensor coefficient calibrated is close to 1.0000, which means
the signal intensity of flow of sensor measures up to the requirement. A sensor coefficient
greater than 1.0000 means low flow sensitivity, while a sensor coefficient smaller than 1.0000
means high flow sensitivity. Higher flow sensitivity is conducive to improving measurement
stability and accuracy of flow meters.
In principle, the MTF 250mA excitation converter can matches well with any common sensors
of which the coefficient is calibrated below 1.0000.
Battery life corresponding measurement cycle time
measurement cycle time | 50mA excitation life | 20mA excitation life |
15s | 50 months | 70 months |
14s | 46 months | 65 months |
13s | 43 months | 60 months |
12s | 40 months | 56 months |
11s | 36 months | 51 months |
10s | 32 months | 46 months |
9s | 29 months | 42 months |
8s | 25 months | 37 months |
7s | 21 months | 32 months |
6s | 18 months | 28 months |
5s | 14 months | 23 months |
4s | 11 months | 18 months |
3s | 10 months | 14 months |