500W Single Output Switching Power Supply
Negotiable /Piece
Min.Order:10 Pieces
Yueqing Ledisen Imp. & Exp. Co., Ltd.
500W Single Output Switching Power SupplAC input
Protections: Short circuit/Over load/Over voltage/Over temperature
Forced air cooling by built-in DC fan
Built-in cooling Fan ON-OFF control
Built-in remote ON-OFF control
Built-in remote sense function
MODEL | S-500-12 | S-500-13.5 | S-500-15 | S-500-24 | S-500-27 | S-500-48 | |
---|---|---|---|---|---|---|---|
OUTPUT | DC VOLTAGE | 12V | 13.5V | 15V | 24V | 27V | 48V |
RATED CURRENT | 40A | 36A | 32A | 20A | 18A | 10A | |
CURRENT RANGE | 0 ~ 40A | 0 ~ 36A | 0 ~ 32A | 0 ~ 20A | 0 ~ 18A | 0 ~ 10A | |
RATED POWER | 480W | 486W | 480W | 480W | 486W | 480W | |
RIPPLE & NOISE (max.) Note.2 | 240mVp-p | 240mVp-p | 240mVp-p | 240mVp-p | 200mVp-p | 300mVp-p | |
VOLTAGE ADJ. RANGE | 10 ~ 13.2V | 12 ~ 15V | 13.5 ~ 18V | 20 ~ 26.4V | 26 ~ 32V | 41 ~ 56V | |
VOLTAGE TOLERANCE Note.3 | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE, HOLD TIME | 200ms, 50ms, 20ms at full load | ||||||
INPUT | VOLTAGE RANGE | 180 ~ 264VAC (110VAC input can be custom-made) | |||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||
EFFICIENCY (Typ.) | 84% | 84% | 84% | 86.0% | 87.0% | 88% | |
AC CURRENT | 7A/115V 3.5A/230V | ||||||
INRUSH CURRENT (max.) | 18A/115V 36A/230V | ||||||
LEAKAGE CURRENT | <3.5mA / 240VAC | ||||||
PROTECTION | OVERLOAD | 105 ~ 135% of rate load | |||||
Protection type: Fold back current limiting, recovers automatically after fault condition is removed | |||||||
OVER VOLTAGE | 13.8 ~ 16.2V | 15.5 ~ 18.2V | 18 ~ 21V | 27.6 ~ 32.4V | 31 ~ 36.5V | 57.6 ~ 67.2V | |
Protection type: Hiccup mode, recovers automatically after fault condition is removed. | |||||||
FAN CONTROL,O.T.P. | |||||||
ENVIRONMENT | WORKING TEMP. | -10 ~ +60ºC (Refer to output load derating curve), 20 ~ 90% RH non-condensing | |||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||
STORAGE TEMP., HUMIDITY | -20 ~ +85ºC, 10 ~ 95% RH | ||||||
TEMP. COEFFICIENT | ±0.03%/ºC (0 ~ 50ºC) | ||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | ||||||
SAFETY & EMC(Note 4) | SAFETY STANDARDS | Design refer to UL1950, TUV EN60950-1 | |||||
WITHSTAND VOLTAGE | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | ||||||
EMI CONDUCTION & RADIATION | Compliance to EN55022 (CISPR22) Class B | ||||||
HARMONIC CURRENT | Compliance to EN61000-3-2,-3 | ||||||
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11;ENV50204,Light industry level,criteria A | ||||||
OTHERS | MTBF | 138.6K hrs min. MIL-HDBK-217F (25ºC) | |||||
DIMENSION | 240*125*65mm (L*W*H) | ||||||
PACKING | 1.35Kgs/pcs, 12pcs/17.7Kgs/0.0326CMB | ||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºCof ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |