240W Industrial DIN-Rail Power Supply(switching power supply)
Negotiable /Piece
Min.Order:10 Pieces
Yueqing Ledisen Imp. & Exp. Co., Ltd.
240W Industrial DIN-Rail Power Supply(switching power supply)
Features:
Universal AC input / Full range
Built in active PFC function
Protections: Short circuit/Over load/Over voltage/Over temperature
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
LED indicator for power on
100% full load burn-in test
Fixed switching frequency at 100KHz
MODEL | DRP-240-24 | DRP-240-48 | |
---|---|---|---|
OUTPUT | DC VOLTAGE | 24V | 48V |
RATED CURRENT | 10A | 5A | |
CURRENT RANGE | 0 ~ 10A | 0 ~ 5A | |
RATED POWER | 240W | 240W | |
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 150mVp-p | |
VOLTAGE ADJ. RANGE | 24 ~ 28V | 48 ~ 53V | |
VOLTAGE TOLERANCE Note.3 | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | |
LOAD REGULATION | ±1.0% | ±1.0% | |
SETUP, RISE TIME | 800ms,40ms/230VAC 800ms, 40ms/115VAC at full load | ||
HOLD TIME(Typ.) | 24ms/230VAC 24ms/115VAC at full load | ||
INPUT | VOLTAGE RANGE Note.5 | 85 ~ 264VAC 120 ~ 370VDC | |
FREQUENCY RANGE | 47 ~ 63Hz | ||
POWER FACTOR (Typ.) | 0.96/230VAC 0.99/115VAC at full load | ||
EFFICIENCY (Typ.) | 84% | 85% | |
AC CURRENT | 2.8A/115VAC 1.4A/230VAC | ||
INRUSH CURRENT(max.) | COLD START 27A/115VAC 45A/230VAC | ||
LEAKAGE CURRENT | <3.5mA/240VAC | ||
PROTECTION | OVERLOAD | 105 ~ 150% rated output power | |
Protection type: Constant current limiting,recovers automatically after fault condition is removed | |||
OVER VOLTAGE | 30 ~ 36V | 54 ~ 60V | |
Protection type: Shut down o/p voltage, re-power on to recover | |||
OVER TEMPERATURE | 100ºC±5ºC (TSW1) Detect on heat sink of power transistor | ||
Protection type: Shut down o/p voltage, recovers automatically after temperature goes down | |||
ENVIRONMENT | WORKING TEMP. | -10 ~ +70ºC (Refer to output load derating curve) | |
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||
STORAGE TEMP., HUMIDITY | -20 ~ +85ºC, 10 ~ 95% RH | ||
TEMP. COEFFICIENT | ±0.03%/ºC (0 ~ 50ºC) | ||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | ||
SAFETY & EMC (Note.4) | SAFETY STANDARDS | Design refer to UL508, UL60950-1, TUV EN60950-1 | |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | ||
EMI CONDUCTION & RADIATION | Compliance to EN55011,EN55022 (CISPR22) Class B | ||
HARMONIC CURRENT | Compliance to EN61000-3-2,-3 | ||
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-2 (EN50082-2) Heavy industry level, criteria A | ||
OTHERS | MTBF | 136.8K hrs min. MIL-HDBK-217F (25ºC) | |
DIMENSION | 125.5*125.2*100mm (L*W*H) | ||
PACKING | 1.2Kg; 12pcs/15.5Kg/1.2CUFT | ||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5.Derating may be needed under lpw input voltages.Please check the derating curve for more details. |