120W Quad Output Switching Power Supply, Power supply
Negotiable /Piece
Min.Order:10 Pieces
Yueqing Ledisen Imp. & Exp. Co., Ltd.
120W Quad Output Switching Power Supply
Protections: Short circuit/Over load/Over voltage
100% full load burn-in test
Fixed switching frequency at 25KHz
MODEL | Q-120B | Q-120C | Q-120D | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
OUTPUT | DC VOLTAGE | 5V | 12V | -5V | -12V | 5V | 15V | -5V | -15V | 5V | 12V | 24V | -12V |
RATED CURRENT | 11A | 4A | 1A | 1A | 10A | 3.5A | 1A | 1A | 8A | 2A | 2A | 1A | |
CURRENT RANGE | 2 ~ 12A | 0.5 ~ 5A | 0.2 ~ 1A | 0.2 ~ 1A | 2 ~ 12A | 0.5 ~ 5A | 0.2 ~ 1A | 0.2 ~ 1A | 2 ~ 12A | 0.2 ~ 5A | 0.2 ~ 2A | 0.2 ~ 1A | |
RATED POWER | 120W | 122.5W | 124W | ||||||||||
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 120mVp-p | 80mVp-p | 120mVp-p | 80mVp-p | 150mVp-p | 80mVp-p | 150mVp-p | 80mVp-p | 120mVp-p | 180mVp-p | 120mVp-p | |
VOLTAGE ADJ. RANGE | CH1: 4.75 ~ 5.5 | ||||||||||||
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±6.0% | ±6.0% | ±6.0% | ±2.0% | +10,-5% | ±6.0% | +10,-5% | ±2.0% | ±6.0% | ±6.0% | ±6.0% | |
LINE REGULATION | ±0.5% | ±1.0% | ±1.0% | ±1.0% | ±0.5% | ±1.0% | ±1.0% | ±1.0% | ±0.5% | ±1.0% | ±1.0% | ±1.0% | |
LOAD REGULATION | ±0.5% | ±5.0% | ±5.0% | ±5.0% | ±0.5% | ±6.0% | ±5.0% | ±6.0% | ±0.5% | ±5.0% | ±5.0% | ±5.0% | |
SETUP, RISE, HOLD TIME | 200ms, 50ms, 20ms at full load | ||||||||||||
INPUT | VOLTAGE RANGE | 88 ~ 132VAC/176 ~ 264VAC selected by switch 240 ~ 370VDC | |||||||||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||||||||
EFFICIENCY (Typ.) | 77% | 76% | 80% | ||||||||||
AC CURRENT | 2.8A/115VAC 1.6A/230VAC | ||||||||||||
INRUSH CURRENT (max.) | COLD START 35A | ||||||||||||
LEAKAGE CURRENT | <3.5mA / 240VAC | ||||||||||||
PROTECTION | OVERLOAD | 105~135% rated output power | |||||||||||
Protection type: Shut down o/p voltage, re-power on to recover. | |||||||||||||
OVER VOLTAGE | CH1:5.75 ~ 6.75VDC | ||||||||||||
Protection type: Shut down o/p voltage, re-power on to recover. | |||||||||||||
ENVIRONMENT | WORKING TEMP. | -10~+60ºC (Refer to output load derating curve) | |||||||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||||||||
STORAGE TEMP., HUMIDITY | -20 ~ +85ºC, 10 ~ 95% RH | ||||||||||||
TEMP. COEFFICIENT | ±0.03%/ºC (0 ~ 50ºC) | ||||||||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | ||||||||||||
SAFETY & EMC (Note.4) | SAFETY STANDARDS | Design refer to UL1950, TUV EN60950 | |||||||||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | ||||||||||||
HARMONIC CURRENT | Compliance to EN61000-3-2,-3, Class A | ||||||||||||
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, Light industry level, criteria A | ||||||||||||
EMI CONDUCTION & RADIATION | Compliance to EN55022 (CISPR22) Class B | ||||||||||||
OTHERS | MTBF | 261.4K hrs min. MIL-HDBK-217F (25ºC) | |||||||||||
DIMENSION | 199*110*50mm (L*W*H) | ||||||||||||
PACKING | 0.81Kg; 16pcs/14.51Kg/0.0287CMB | ||||||||||||
NOTE | 1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation. 4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |