75W Industrial DIN-Rail Power Supply(switching power supply)
Negotiable /Piece
Min.Order:10 Pieces
Yueqing Ledisen Imp. & Exp. Co., Ltd.
75W Industrial DIN-Rail Power Supply(switching power supply)
Features:
Universal AC input/Full range
Protections: Short circuit/Over load/Over voltage/Over temperature
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
LED indicator for power on
100% full load burn-in test
Fix switching frequency at 50KHz
MODEL | DR-75-12 | DR-75-24 | DR-75-48 | |
---|---|---|---|---|
OUTPUT | DC VOLTAGE | 12V | 24V | 48V |
RATED CURRENT | 6.3A | 3.2A | 1.6A | |
CURRENT RANGE | 0 ~ 6.3A | 0 ~ 3.2A | 0 ~ 1.6A | |
RATED POWER | 76W | 76.8W | 76.8W | |
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | 150mVp-p | 240mVp-p | |
VOLTAGE ADJ. RANGE | 12 ~ 14V | 24 ~ 28V | 48 ~ 53V | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | |
SETUP, RISE TIME | 1000ms, 60ms/230VAC 1800ms, 60ms/115VAC at full load | |||
HOLD TIME(Typ.) | 60ms/230VAC 12ms/115VAC at full load | |||
INPUT | VOLTAGE RANGE | 85 ~ 264VAC 120 ~ 370VDC | ||
FREQUENCY RANGE | 47 ~ 63Hz | |||
EFFICIENCY (Typ.) | 76% | 80% | 81% | |
AC CURRENT | 1.6A/115VAC 0.96A/230VAC | |||
INRUSH CURRENT(max.) | COLD START 20A/115VAC 40A/230VAC | |||
LEAKAGE CURRENT | <1mA/240VAC | |||
PROTECTION | OVERLOAD | 105 ~ 150% rated output power | ||
Protection type: Constant current limiting,recovers automatically after fault condition is removed | ||||
OVER VOLTAGE | 15 ~ 16.5V | 29 ~ 34V | 58 ~ 65V | |
Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||
OVER TEMPERATURE | 85ºC±5ºC (TSW1) Detect on heat sink of power transistor | |||
Protection type: Shut down o/p voltage, recovers automatically after temperature goes down | ||||
ENVIRONMENT | WORKING TEMP. | -10 ~ +60ºC (Refer to output load derating curve) | ||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||
STORAGE TEMP., HUMIDITY | -20 ~ +85ºC, 10 ~ 95% RH | |||
TEMP. COEFFICIENT | ±0.03%/ºC (0 ~ 50ºC) | |||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | |||
SAFETY & EMC (Note.4) | SAFETY STANDARDS | Design refer to UL508,TUV EN60950-1 | ||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | |||
EMI CONDUCTION & RADIATION | Compliance to EN55022 (CISPR22) Class B | |||
HARMONIC CURRENT | Compliance to EN61000-3-2,-3 | |||
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-2 (EN50082-2) Heavy industry level, criteria A | |||
OTHERS | MTBF | 123.1K hrs min. MIL-HDBK-217F (25ºC) | ||
DIMENSION | 55.5*125.2*100mm (L*W*H) | |||
PACKING | 0.6Kg; 20pcs/13Kg/1.1CUFT | |||
NOTE | 1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |