Winner 2009B large-range wet-process high-performance he-neon blue laser particle size analyzer

Winner 2009B large-range wet-process high-performance he-neon blue laser particle size analyzer

USD $1998 - $28578 /Set

Min.Order:1 Set

Supply Ability:
500 Set / Sets per Month
Port:
Qingdao/kangkong
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other

Quick Details View All >

Brand Name:
Winner
Place of Origin:
China
Model Number:
Winner 2009B

Jinan Winner Particle Instrument Stock co.itd

Business license
Business Type: Manufacturer
Main Products: Laser Diffraction Particle Size Analyzer ,Nano Particle Size Analyzer ,Spray Particle Size Analyzer ,Particle Image Analyzer for particle characterization

Product Details

Product Description
Winner2009B full automatic wet laser particle size analyzer adopt MIE scattering principle, measure size is from 0.01μm to 2000μm, Which offer reliable and repeatable particle size analysis for a diverse range of applications.It use dual-beam& multiple spectral detection systems and side light scatter test technology to significantly improve precision and performance of test, on behalf of the domestic advanced level in the field.

Main Features                                                                                                                      
(1)Winner Patent -Optical path design
Converging light Fourier transform light patented technology, make scattering light not be restricted to lens aperture. Double spectrum design make its precision achieves from 0.01μm to 2000μm/1200μm,and Dual-laser orthogonal light make use of the semiconductor auxiliary laser extend the test angle from 45 degree to 135 degree, ensure receive all the angles of signals.

(2) Expand Size Range
Winner2008A/B measurement range significantly expanded to 0.01μm, particularly suitable for small samples of the user, the sub micron particle test results reached the international level

(3)Full automatic built-in wet dispersion system
The ultrasonic dispersion, mechanical stirring and circulation channel reasonable integrated in the interior of the instruments, ensure the uniform dispersion and distribution of particles in the testing process, effectively avoid uneven distribution, large particle deposition phenomenon caused by long pipe line of outside dispersion system , to ensure the accuracy of the test results.

(4) Intelligent Operation mode
With intelligent automatic mode of operation, to achieve a key test, as long as according to the prompt addition of sample, click the "test", all processes including water-supply, dispersion, circulation, testing, cleaning, data record, data analysis, save and print are automatically completed, not only reduce the testing workload, but also eliminate the interference of human factors, to further improve the accuracy and authenticity of testing results.

(5)Automatic Optical path alignment system

The precision of four hybrid stepping motor in the automatic system of optical components, micro precision of 0.01μm, the instrument of light path is always at its best to eliminate manually on the light path and the troubles and difficulties but also enhance the accuracy and stability of test results.

(6)Authoritative calibration method
In the entire test range using the national standard materials for calibration, only a year calibration once the instrument can. Calibration method is simple and quick.

(7) Unconstrained free fitting patent technique

Winner original unconstrained free fitting patent technology, particle size analysis is not affected by any functional constraints, truely refelect particle size distribution.

Specification
Model Name

Winner2009B
Standard
ISO13320-1:1999, GB/T19077.1-2008, Q/JWN001-2009
Principle
MIE scattering principle
Measuring Range

0.01μm-1200μm
Channels Number

120 (different photo detectors & optical light path)
Accuracy error
≤0.5% (Deviation of D50 on national standard sample)
Repeatability error
≤0.5% (Deviation of D50 on national standard sample )
Light source
High performance He-Ne Laser (λ= 632.8nm, P>2MW)
Lifetime>25000hours

Dispersion
Method
Ultrasonic
Frequency:40KHz Power:35W, Time: ≥1S ,Anti-dry function
Stir
Revolutions Speed: 0-3000RPM (Adjustable)
Circulate
Rated Flow:8L/min Rated Power:10W
Sample Pool
Volume:350mL
Micro-
Sample Pool
Volume: 10mL ( Available)
Operation Mode
Full automatic/ manual control, freely choose
Resolution
Free distribution truly reflect particle size distribution
Optical bench alignment system
Japan Canon lens, Full automatic,precision is up to 0.1um
Software function
Analysis mode
Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc.
Statistic Method
Volume Distribution, Quantity Distribution
Statistic Comparison
Several Testing Results of samples
Different batches of samples testing result,
Samples before and after processing,
Test result of samples in different time.
User-defined Analysis
Figure out percentage according to the particle size
Figure out particle size according to the percentage
Figure out percentage according to the particle size range
Meet demands of representation of particle test in different industries
Test Report
Word, Excel,Photo( Bmp), Text etc
Multiple-language Support
Multiple language Support
Intelligent operation
Automatically control water inflow, dispersion,test and analysis.Better Repeatability after remove human-factor
Testing speed
<2min/time
Outer dimension
Host machine :L120cm*W37cm*H56cm 
Wet dispersion box: L44.2cm*W28cm*H34.2cm
58Net weight
58kg+15kg
Our Team                                                                                                                     
Our goal is to provide super quality and competitive price laser particle size analyzer for clients all over the world!

We created more than 30 first particle size analysis technology in China!

Principle                                                                                                                                
Test Operation Interface:                                                                                                                                


Quality Assurance                                                                                                                                

(1) Laser particle size analyzer uses Mie scattering theory

(2) High-efficiency cost mode, semi-automatic button operation.

(3) The laser particle size analyzer adopts a fully built-in integrated dispersion system, including ultrasonic stirring, ultrasonic dispersion and circulation system to prevent the deposition of large particles in the pipeline.

(4) The laser particle size analyzer adopts a unique unconstrained free fitting technology, so that particle analysis is not restricted by any function, truly reflects the particle distribution, and ensures good accuracy.

(5) The laser particle size analyzer uses a converged light Fourier transform optical path to effectively improve the resolution of sub-micron particles.

(6) The laser particle size analyzer adopts logarithmic main and auxiliary detectors to ensure effective capture of scattered signals.

 

After Sale Service

                                                                                                           

1. Provide operation demonstration video.

2. Provide free installation and training services.

3. The warranty period is 1 year after receipt of the goods, and technical support is provided for life.

4. If repair parts are provided, we will provide parts at favorable prices, only charge cost prices, and provide long-term maintenance.

Packing & Delivery

Winner particle testing equipment is Wooden box package.


We would ship machine by DHL, FeDex, China express, by sea and by air.

Contact Supplier

Ms. Chat Now

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Other Measuring & Analysing Instruments
Categories
Hi~