Winner 2309A Unconstrained free Fitting technology particle size analyzer for particle size distribution
Winner 2309A Unconstrained free Fitting technology particle size analyzer for particle size distribution
Winner 2309A Unconstrained free Fitting technology particle size analyzer for particle size distribution
Winner 2309A Unconstrained free Fitting technology particle size analyzer for particle size distribution
Winner 2309A Unconstrained free Fitting technology particle size analyzer for particle size distribution

Winner 2309A Unconstrained free Fitting technology particle size analyzer for particle size distribution

USD $9998 - $33598 /Set

Min.Order:1 Set

Supply Ability:
500 Set / Sets per Month
Port:
Qingdao/kangkong
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other

Quick Details View All >

Brand Name:
winner
Place of Origin:
China
Model Number:
Winner 2309A

Jinan Winner Particle Instrument Stock co.itd

Business license
Business Type: Manufacturer
Main Products: Laser Diffraction Particle Size Analyzer ,Nano Particle Size Analyzer ,Spray Particle Size Analyzer ,Particle Image Analyzer for particle characterization

Product Details

Product Description


Winner2309A is intelligent full automatic laser particle size analyzer,adopt MIE scattering principle, which is integrated model of wet and dry dispersion system. It’s the prior choice for industrial production quality control departments and research institutions which have more types of particles and wide particle size distribution.


Main Features

(1)Wet and dry, seperated dispersion unit
This instrument integrated wet and dry dispersion test in one, successfully resolved the problem of dry and wet technology integration, realize one key to switch.

(2) Intelligent full automatic operation system and manual operation, freely choose.
Choose automatic mode, very easy and simple to learn,support one key operation.

(3)Optical Path System patented technology
Converging light Fourier transform path system, enables scattering light be not restricted to the lens aperture limit, and the dual laser orthogonal light use auxiliary semiconductor laser to expand the measurement range by enlarge scattering angle from 45 degrees to 135 degrees.

(4) Automatic Optical path alignment System,
which is composed of precise four phase hybrid stepper motor, Its inching precision is reach to micron level,make optimum optical paths to ensure accurate and stable test.

(5) Full built-in Sample dispersion system.
set mechanical stirring, ultrasonic dispersion, and circulation path in one, It ensures particles uniform dispersion and distribution,avoids many bad phenomenon, such as uneven distribution of particles, large particles deposit because of the long outer dispersing system tube, And it guarantees the representativeness of test result.

(6)Instrument Software
Original Unconstrained free fitting technology collect scattering data during the measurement process, make particle analysis not be restricted by any functions, truly reflect particles distribution.


Specification


Model Name
Winner2309A
Standard
ISO13320-1:2009,GB/T19007-2016,Q/0100JWN001-2013
Compliance with 21 CFR Part 11
Principle
Laser diffraction principle
Analysis
Mie and Fraunhofer scattering
Detector Arrangement
Log-spaced array, test angle from 0.015 degree to 145 degree
Measuring Range
Wet:0.01μm-2000 μm Dry: 0.1μm-2000μm 
Silicon Photodetectors
Wet:127 pcs Dry:100 pcs
Accuracy error
Wet≤0.5% Dry≤1% (CRM D50)
Repeatability error
Wet≤0.5% Dry≤1% (CRM D50)
Light source
High performance semiconductor red laser (λ=639nm )
P>3.0MW
Auxiliary green solid semiconductor laser (λ= 405 nm)
P>2.0MW (available)
Optical path
Converging light Fourier transform optical path
Effective focal length
500mm
Laser Safety
Class 1
Wet dispersion
Ultrasonic
Frequency:40KHz Power:60W, Time: ≥1S
Stir
Revolutions Speed: 0-3000RPM (Adjustable)
Circulate
Rated Flow:30L/min Rated Power:70W
Water level sensor (UK
Prevent water overflow and effectively protect the instrument
Sample tank
Volume:1000mL
Micro-
Sample cuvette
Volume: 10mL ( Available)
Dry dispersion
Dry-turbulence dispersion patent technology, normal shock wave shear technique
Feeding Speed
Adjustable (Variable speed knob)
Operation Mode
Full automatic / manual control, freely choose
Dispersion medium
Compressed Air, pressure: 0 to 6 bar
Optical bench alignment system
Full automatic, precision is up to 0.2um
Full Test Speed per time
Wet: <2 Min Dry :<1min
Inverval time per test result :500ms
Outer dimension
Host machine: L120cm×W37cm×H56cm 
wet distribution box: L44.2cm×W28cm×H34.2cm
Net Weight
62Kg+15Kg

Application

Winner2309A widely used in cement, ceramics, medicines, lotions, paints, dyes, pigments, fillers, chemicals, catalysts, drilling mud, abrasives, lubricants, coal, sediment, dust, cells, bacteria, food additives, pesticides, explosives, graphite, photographic materials, fuel, ink, metal and non-metal powder, calcium carbonate, kaolin, coal slurry and other powdered materials.


Quality Assurance

1. Strictly conforming to ISO9001-2000 quality management system.

2. Strict control from purchasing materials, process inspection to final particle size distribution test.
3. QC department to execute quality control regulations.
4.Only qualified components will be assembled and total laser particle size analyzer must be inspected     completely before sale.
5.Laser particle size analyzer will be processed preventing -shake test before delivery.

After Sale Service

1. Provide operation demonstration video.

2. Provide free installation and training services.

3. The warranty period is 1 year after receipt of the goods, and technical support is provided for life.

4. If repair parts are provided, we will provide parts at favorable prices, only charge cost prices, and provide long-term maintenance.




Packing List

NO.
Items
Quantity
Unit
1
Winner2309 laser particle size analyzer
1
Set
2
Software
1
Set
3
Software key
1
PCS
4
Standard sample
1
Bottle
5
Power cable
1
PCS
6
Communication cable
1
PCS
7
Sample cuvette
1
PCS
8
Screwdriver
2
PCS
9
Wrench
3
PCS
10
Draining water pipeline
1
PCS
11
Standard sample pipeline
1
Set
12
Clean mirror paper
3
PCS
13
Clean mirror card
1
PCS
14
Sample cuvette brush
2
PCS
15
Spoon
2
PCS
16
2A fuse
5
PCS
17
Quality certificate
1
PCS
18
Warranty Card
1
PCS
19
Manual
1
PCS


FAQ

Purchase laser particle size analyzer need know points:

(1) What materials need test?
If suspension/emulsion, must choose liquid dispersion particle size analyzer, and some materials are also reacted with water, so need liquid dispersion particle size analyzer also. Generally, cement, metal powders and pharamcy materials need dry dispersion model particle size analzyer.

(2) What size range need test?
By now, Based on MIE scattering, laser particle size analyzer can test the particle range is 0.01um-2000um.
If materials range is not so wide, for example, 10um-20um, smaller range of particle size distributon choose closer range model will be preciser, no need to buy large range model.

(3) What is dispersion media?
For liquid model, in order that sample can disperse well and circualte in the laser particle size analyzer, generally we need use water, alochol or organic solvent as dispersion media.For dry dispersion model, just use compressed air as dispersion media.In the current market, Dry laser particle size analyzer cost is higher than liquid dispersion models, so if can test well, liquid model is better.

More questions, please contact us, we will offer you the best suitable laser particle size analyzer for you!


Contact Supplier

Ms. Chat Now

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Measuring & Analysing Instrument Stocks
Categories
Hi~