Winner 2308A Wet/Dry method laser particle size distribution analyzer for particle characteristic measurement
Winner 2308A Wet/Dry method laser particle size distribution analyzer for particle characteristic measurement
Winner 2308A Wet/Dry method laser particle size distribution analyzer for particle characteristic measurement
Winner 2308A Wet/Dry method laser particle size distribution analyzer for particle characteristic measurement
Winner 2308A Wet/Dry method laser particle size distribution analyzer for particle characteristic measurement

Winner 2308A Wet/Dry method laser particle size distribution analyzer for particle characteristic measurement

20998 - 27998 /Set

Min.Order:1 Set

Supply Ability:
500 Set / Sets per Month
Port:
Qingdao/kangkong
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other

Quick Details View All >

Brand Name:
winnner
Place of Origin:
China
Model Number:
Winner 2308A

Jinan Winner Particle Instrument Stock co.itd

Business license
Business Type: Manufacturer
Main Products: Laser Diffraction Particle Size Analyzer ,Nano Particle Size Analyzer ,Spray Particle Size Analyzer ,Particle Image Analyzer for particle characterization

Product Details

Product Description

Winner2308A intelligent full automatic wet&dry laser particle size analyzer adopt laser diffraction theory(Mie and Fraunhofer diffraction), measure size is from 0.01μm to 2000μm(dry 0.1μm-2000μm), Which offer reliable and repeatable particle size analysis for a diverse range of applications.It use dual-beam& multiple spectral detection systems and side light scatter test technology to significantly improve precision and performance of test, It’s the prior choice for industrial production quality control departments and research institutions.


Main Features

(1)Wet and dry sample dispersion system Integrated Design
Winner2308 intelligent laser particle size analyzer which is 1st set laser particle size analyzer integrated wet and dry dispersion test in one in China, it successfully resolved the problem of dry and wet technology integration, realize one key to switch, apply to test all the particle size distribution from 0.01μm-2000μm particles.

(2) Intelligent full automatic operation system and manual operation mode, freely choose.
With intelligent automatic mode of operation, to achieve a key test, as long as according to the prompt addition of sample, click the "test", all process will be complete automatically, not only reduce the testing workload, but also eliminate the interference of human factors, to further improve the accuracy and authenticity of testing results.

Wet method: A key to complete water-supply, ultrasonic dispersion, circulation, testing, cleaning, data record, data analysis,save and print are automatically completed, only take 2 mins.

Dry method: A key to complete the dust collecting, compressed air supply, feeding, testing(The patented technology of turbulence dispersion and the sample window of the negative pressure device make the sample be fully dispersed), data processing and other operation, take 1 min.

(3) Stable and unique optical path system patented technology
Converging light Fourier transform path patent technology, enables scattering light be not restricted to the lens aperture limit,using Double Spectral plane optical path design, the Photodetector channels are 127 pcs, the maximum detection angle is 145 degrees and the minimum detection angle is 0.0155 degrees, Using dual-laser orthogonal light patent technology, The measurement range is effectively extended to 2000 microns. Canon Fourier lens imported from Japan is used to ensure the stability and accuracy
of particle measurement.

(4) Automatic Optical path alignment System,
The precision of four hybrid stepping motor in the automatic system of optical components, micro precision of 0.1um, the instrument of light path is always at its best to eliminate manually on the light path and the troubles and difficulties but also enhance the accuracy and stability of test results.


(5) Full built-in Sample Wet and dry dispersion system,One key switch.
Auto wet dispersion system,SOP realize one key operation.
set mechanical stirring, ultrasonic dispersion, and circulation path in one, It ensures particles uniform dispersion and distribution,avoids many bad phenomenon, such as uneven distribution of particles, large particles deposit because of the long outer dispersing system tube, And it guarantees the representativeness of test result.

For dry dispersion system, Turbulence dispersion patented technology and Normal shock shearing effect, make particles sufficient
dispersion,ensure good test,apply to test powders range from 0.1 micron to 1200 micron.

( 6)Instrument Software

Original Unconstrained free fitting patent technology collect scattering data during the measurement process, make particle analysis not be restricted by any functions, truly reflect particles size distribution, The instrument provide high precision data with  10Khz data acquisition time.


Specification

Model Name
Winner2308A
Standard
ISO13320-1:2009,GB/T19007-2016,Q/0100JWN001-2013
Compliance with 21 CFR Part 11
Principle
Laser diffraction principle
Analysis
Mie and Fraunhofer scattering
Detector Arrangement
Log-spaced array, test angle from 0.015 degree to 145 degree
Measuring Range
Wet:0.01μm-2000 μm Dry: 0.1μm-2000μm
Silicon Photodetectors
Wet:127 pcs Dry:100 pcs
Accuracy error
Wet≤0.5% Dry≤1% (CRM D50)
Repeatability error
Wet≤0.5% Dry≤1% (CRM D50)
Light source
High performance semiconductor red laser (λ=639nm )
P>3.0MW
Auxiliary green solid semiconductor laser (λ= 405 nm)
P>2.0MW (available)
Optical path
Converging light Fourier transform optical path
Effective focal length
500mm
Laser Safety
Class 1
Wet dispersion
Ultrasonic
Frequency:40KHz Power:60W, Time: ≥1S
Stir
Revolutions Speed: 0-3000RPM (Adjustable)
Circulate
Rated Flow:30L/min Rated Power:70W
Water level sensor (UK
Prevent water overflow and effectively protect the instrument
Sample tank
Volume:1000mL
Micro-
Sample cuvette
Volume: 10mL ( Available)
Dry dispersion
Dry-turbulence dispersion patent technology, normal shock wave shear technique
Feeding Speed
Adjustable (Variable speed knob)
Operation Mode
Full automatic / manual control, freely choose
Dispersion medium
Compressed Air, pressure: 0 to 6 bar
Optical bench alignment system
Full automatic, precision is up to 0.2um
Full Test Speed per time
Wet: <2 Min Dry :<1min
Inverval time per test result :500ms
Outer dimension
L104cm×W44cm×H54cm
Net Weight
58Kg

Application

Winner2308A widely used in cement, ceramics, medicines, lotions, paints, dyes, pigments, fillers, chemicals, catalysts, drilling mud, abrasives, lubricants, coal, sediment, dust, cells, bacteria, food additives, pesticides, explosives, graphite, photographic materials, fuel, ink, metal and non-metal powder, calcium carbonate, kaolin, coal slurry and other powdered materials.



Quality Assurance

1. Strictly conforming to ISO9001-2000 quality management system.

2. Strict control from purchasing materials, process inspection to final particle size distribution test.
3. QC department to execute quality control regulations.
4.Only qualified components will be assembled and total laser particle size analyzer must be inspected     completely before sale.

5.Laser particle size analyzer will be processed preventing -shake test before delivery.


After Sale Service


1. Provide operation demonstration video.

2. Provide free installation and training services.

3. The warranty period is 1 year after receipt of the goods, and technical support is provided for life.

4. If repair parts are provided, we will provide parts at favorable prices, only charge cost prices, and provide long-term maintenance.