Winner 3009A  CE certificate micron powder Dry Dispersion laser Particle Size Analyzer for particle size distribution
Winner 3009A  CE certificate micron powder Dry Dispersion laser Particle Size Analyzer for particle size distribution
Winner 3009A  CE certificate micron powder Dry Dispersion laser Particle Size Analyzer for particle size distribution
Winner 3009A  CE certificate micron powder Dry Dispersion laser Particle Size Analyzer for particle size distribution
Winner 3009A  CE certificate micron powder Dry Dispersion laser Particle Size Analyzer for particle size distribution

Winner 3009A CE certificate micron powder Dry Dispersion laser Particle Size Analyzer for particle size distribution

USD $12599 - $25999 /Set

Min.Order:1 Set

Supply Ability:
500 Set / Sets per Month
Port:
Qingdao/kangkong
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other

Quick Details View All >

Brand Name:
winner
Place of Origin:
China
Model Number:
Winner 3009A

Jinan Winner Particle Instrument Stock co.itd

Business license
Business Type: Manufacturer
Main Products: Laser Diffraction Particle Size Analyzer ,Nano Particle Size Analyzer ,Spray Particle Size Analyzer ,Particle Image Analyzer for particle characterization

Product Details

Product Description

Winner3009A intelligent dry laser particle size analyzer, manual and full automatic operation modes. MIE scattering principle as basic, Converging light Fourier transform light path, Highly stable He-Ne laser and High sensitive ring photoelectric detector,guarantee good repeatability and accuracy.

It use air as dispersion medium, and use turbulent dispersion principle with High precision feeding device, patent powder spray pump and oil-free silent gas source guaranteeing the samples to be fully dispersed. It’s fit for any dry powder materials,especially the powder that takes chemical reaction with water or changes its shape in liquid. Compared to the wet laser particle size analyzer, It’s with the same accuracy and repeatability.


Main Features

(1) Advanced testing optical path.

Converging light Fourier transform light patented technology, make scattering light not be restricted to lens aperture. Use main detector and large angle auxiliary detector efficiently collect all angles of scattering light in the testing range, ensure good testing accuracy and reliability in the whole range.

(2)Scientific dispersion system
Turbulence dispersion patented technology and Normal shock shearing effect, make particles sufficient dispersion, Adopt wearable ceramics improve dispersion system’s working life.

(3)Human-based operation mode Manual and Full automatic, easy choose.

(4)High precision-automatic optical path calibration system
It’s composed of precise four phase hybrid stepper motor, Its inching precision is reach to micron level, so light path is always in a good state.

(5)Intelligent data analysis-winner unique software support
Analysis software collect large quantity of particle information in high speed, and inverse particle distribution by unconstrained free fitting technology, then intelligent statistics and analysis of testing data, ensure accuracy and repeatability of the output.

(6) The results not only show particle distribution,the cumulative value curve and typical particle sizes( D10, D50, D90.), but also support user-defined analyze result, such as any features particle diameter from D0 to D100,Cumulative percent(bigger than or less than a certain particle diameter).

(7)Users can design the test report output and display forms according to industry requirements.


Specification

Model
Winner3009A
Standard
ISO 13320-1:1999;GB/T19077.1-2308;Q/0100JWN001-2013
Measuring Range
0.1-2000μm
Channels Number
100
Accuracy
<1% (Deviation of D50 on national standard sample)
Repeatability
<1% (Deviation of D50 on national standard sample )
Light source
He-Ne laser (λ= 632.8nm, P>2.0MW)
Dispersion
Dry-turbulence dispersion mode, normal shock wave shear technique
Operation Mode
Manual & Full automatic
Operation temperature
+5°C to +40°C
Feeding
Automatic vibration feeding
Optical Calibration System
Automatic
Software function
Analysis mode
Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc.
Statistic Method
Volume Distribution, Quantity Distribution
Statistic Comparison
Several Testing Results of samples
Different batches of samples testing result,
Samples before and after processing,
Test result of samples in different time.
User-defined Analysis
Figure out percentage according to the particle size
Figure out particle size according to the percentage
Figure out percentage according to the particle size range
Meet demands of representation of particle test in different industries
Test Report
Word, Excel,Photo( Bmp), Text etc
Multiple language Support
Multiple language Support
Intelligent operation
Better Repeatability after remove human-factor
Test Speed
<1min for each time
Power supply
220V
Volume
L105cm×W44cm×H54cm
Net Weight
58Kg


Application

Particle size analyzer is  widely used for cement, ceramic, medicine, dope, dye, padding, chemical products, catalyst, braize, dust, additive,pesticide, explosive, graphite, photosensitive material, fuel, metal and nonmetal powder, calcium carbonate, kaolin and other powder materials.


Our Team

Our goal is to provide super quality and competitive price laser particle size analyzer for clients all over the world!
We created more than 10 first particle size analysis technology in China!


Quality Assurance

1. Strictly conforming to ISO9001-2000 quality management system.

2. Strict control from purchasing materials, process inspection to final particle size distribution test.
3. QC department to execute quality control regulations.
4.Only qualified components will be assembled and total laser particle size analyzer must be inspected     completely before sale.

5.Laser particle size analyzer will be processed preventing -shake test before delivery.


After Sale Service

1. Provide operation demonstration video.

2. Provide free installation and training services.

3. The warranty period is 1 year after receipt of the goods, and technical support is provided for life.

4. If repair parts are provided, we will provide parts at favorable prices, only charge cost prices, and provide long-term maintenance.

FAQ

Purchase laser particle size analyzer need know points:

(1) What materials need test?
If suspension/emulsion, must choose liquid dispersion particle size analyzer, and some materials are also reacted with water, so need liquid dispersion particle size analyzer also. Generally, cement, metal powders and pharamcy materials need dry dispersion model particle size analzyer.

(2) What size range need test?
By now, Based on MIE scattering, laser particle size analyzer can test the particle range is 0.01um-2000um.
If materials range is not so wide, for example, 10um-20um, smaller range of particle size distributon choose closer range model will be preciser, no need to buy large range model.

(3) What is dispersion media?
For liquid model, in order that sample can disperse well and circualte in the laser particle size analyzer, generally we need use water, alochol or organic solvent as dispersion media.For dry dispersion model, just use compressed air as dispersion media.In the current market, Dry laser particle size analyzer cost is higher than liquid dispersion models, so if can test well, liquid model is better.

More questions, please contact us, we will offer you the best suitable laser particle size analyzer for you!






Contact Supplier

Ms. Chat Now

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Measuring & Analysing Instrument Stocks
Categories
Hi~