Winner 319 1um-500um small spray equipment medical nebulizers used spray laser particle size analyzer
Winner 319 1um-500um small spray equipment medical nebulizers used spray laser particle size analyzer
Winner 319 1um-500um small spray equipment medical nebulizers used spray laser particle size analyzer
Winner 319 1um-500um small spray equipment medical nebulizers used spray laser particle size analyzer
Winner 319 1um-500um small spray equipment medical nebulizers used spray laser particle size analyzer

Winner 319 1um-500um small spray equipment medical nebulizers used spray laser particle size analyzer

USD $12998 - $21998 /Set

Min.Order:1 Set

Supply Ability:
500 Set / Sets per Month
Port:
Qingdao/kangkong
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other

Quick Details View All >

Brand Name:
Winner
Place of Origin:
China
Model Number:
Winner 319A/ Winner 319 B/ Winner 319C

Jinan Winner Particle Instrument Stock co.itd

Business license
Business Type: Manufacturer
Main Products: Laser Diffraction Particle Size Analyzer ,Nano Particle Size Analyzer ,Spray Particle Size Analyzer ,Particle Image Analyzer for particle characterization

Product Details

Product Description

Winner319 is a desktop spray laser particle size analyzer specially designed and developed for droplet size testing. The instrument adopts the principle of Fraunhofer diffraction and the parallel optical path design of high-performance and high-power lasers, which can meet the requirements of droplet testing. And the test range can be adjusted according to customer requirements.


Specification

Models
Winner319A
Winner319B
Winner319C
Executive Standard
ISO13320-1:1999,GB/T19077.1-2008,Q/0100JWN001-2013
Principle
Fraunhofer diffraction principle
Instrument Structure
Split-Type
Testing Range
1μm-500μm
1μm-1000μm
1μm-2000μm
Number of Channels
50 pcs
51 pcs
58 pcs
Accuracy error
<1% (Reference to CRM D50)
Repeatability error
<1% (Reference to CRM D50)
Reproducibility between instruments
<1% (Reference to CRM D50)
Data Acquisition Rate
≧2KHZ
Laser

LD Pump Laser;λ=532nm, p>40mw, life time>25000 hour
Laser safety
Class 3B
Air purging system
Equipped with airflow protection device, which can effectively protect the lens and avoid droplet pollution to lens in testing
process.
Sampling Mode
Open Style
Optical alignment system
Automatic
Working temperature
10-40°C
Environment humidity
≤75%
Operation platform
Common model, Windows 7/8/10 (64 bits) need install Office 2003
Output parameters
Particle volume distribution curve, D10-D100 any parameters
Testing Area Length
0.1-10m/adjustable
Lens Protection
Double gas episodic
Outer Dimension
Transmit port: L369*W295*H360mm Receive port:L858*W295*H360mm
Power Supply
220V, 50HZ
Weight
68KG
Product Details

Winner319 Industrial laser particle size analyzer is a specially designed and developed bench-top spray laser particle size analyzer for droplet size test. This instrument adopts Laser diffraction &Fraunhofer diffraction principle and parallel light path design with high-performance and high-power laser, lifetime>25000hours, which can meet the requirements of droplet test. And the test range can be adjusted according to the customers’ requirement.


Main Features
1, Exclusive patent technologyIt adopts representative Parallel optical testing technology and Spectrum amplification technique and realizes the wide range expansion in limited space. Besides, it adds several Auxiliary integration photoelectric detector, which can effectively collect scattering light from every angle in the testing range, realizing the testing accuracy and reliability in the whole range. 2, Unique Airflow Protection Device It has airflow protection device, which can effectively protect the lens and avoid droplet pollution to lens in testing process. 3, Split-Type Structure Design Split-Type structure and adjustable test area can meet the needs of the spray test in any conditions and It has many specialties, such as non-contact measurements, non-interfering etc. 4,Stable automatic optical path alignment system Remove adjusted difficulty caused by the light path movement, the light path alignment system can be corrected by a key 5,Multiple size distribution model

Free choice standard model, RR distribution and Lognormal distribution. Can convert the volume distribution and individual number distribution freely.


Quality Assurance

1. Strictly conforming to ISO9001-2000 quality management system.

2. Strict control from purchasing materials, process inspection to final particle size distribution test.
3. QC department to execute quality control regulations.
4.Only qualified components will be assembled and total laser particle size analyzer must be inspected     completely before sale.

5.Laser particle size analyzer will be processed preventing -shake test before delivery.



After Sale Service

1.Operation demo video CD will be offered.

2. Offer free-training service.
3. The quality assurance date is 1 year since finishing payment, Technology support will be provided for life. And after that, we will collect the cost if provide repair accessories.
4. Maintenance for equipment failure caused by improper handling (appropriate cost will be collected).
5. We offer the components with favorable price and perdurable maintenance.


Packing & Delivery

Winner particle testing equipment is Wooden box package.


We would ship machine by DHL, FeDex, China express, by sea and by air.



FAQ

Purchase laser particle size analyzer need know points:
(1) What materials need test?
If suspension/emulsion, must choose liquid dispersion particle size analyzer, and some materials are also reacted with water, so need liquid dispersion particle size analyzer also. Generally, cement, metal powders and pharamcy materials need dry dispersion model particle size analzyer.

(2) What size range need test?
By now, Based on MIE scattering, laser particle size analyzer can test the particle range is 0.01um-2000um.
If materials range is not so wide, for example, 10um-20um, smaller range of particle size distributon choose closer range model will be preciser, no need to buy large range model.

(3) What is dispersion media?
For liquid model, in order that sample can disperse well and circualte in the laser particle size analyzer, generally we need use water, alochol or organic solvent as dispersion media.For dry dispersion model, just use compressed air as dispersion media.In the current market, Dry laser particle size analyzer cost is higher than liquid dispersion models, so if can test well, liquid model is better.

More questions, please contact us, we will offer you the best suitable laser particle size analyzer for you!








Contact Supplier

Ms. Chat Now

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Measuring & Analysing Instrument Stocks
Categories
Hi~