Product Description
Winner2005A/B intelligent full automatic laser diffraction particle size analyzer with MIE scattering theory to precisely test the particle size distribution from 0.01/0.1μm to 1000μm. It adopts dual laser beam and built-in sample preparation system, Intelligent operation, very simple to use for engineer, offer accurate and reliable data,built-in side wide-angle detector, make sure get 0.01 micron particles scattering angles.
Main Features
(1) Light path: Adopt converging light Fourier transform light path,measure range expanded from 0.01μm-1000μm.
(2)Intelligent full automatic operation mode realize one key test, automatically supply water,ultrasonic dispersion, circulate and drain off water, so it not only could decrease workload, but also get better repeatability after remove human-factors errors.
(3) Automatic Optical path alignment System,
The precision of four hybrid stepping motor in the automatic system of optical components, micro precision of 0.01μm, the instrument of light path is always at its best to eliminate manually on the light path and the troubles and difficulties but also enhance the accuracy and stability of test results.
(4)Full built-in Sample dispersion system,
Auto wet dispersion system,SOP realize one key operation.
set mechanical stirring, ultrasonic dispersion, and circulation path in one, It ensures particles uniform dispersion and distribution,avoids many bad phenomenon, such as uneven distribution of particles, large particles deposit because of the long outer dispersing system tube, it guarantees the representativeness of test result.
(5) Analysis software:adopt unconstrained free fitting patent technology make particle analysis not be restricted by any functions, truly reflect particle size distribution.
(6) High sensitive photo detectos gathering all the particles scattering signals, ensure the good accuracy.
(7)Output parameters:(D50, D03, D06, D10, D16, D25, D75, D84, D90, D97,D98,set any value, S/V, D[3,2],D[4,3] )
Model Name | Winner2005A |
Standard | ISO13320-1:1999,GB/T19077.1-2008,Q/0100JWN001-2013 |
Principle | MIE Scattering Principle |
Size range | 0.01μm-1000μm |
Photodetectos | 90pcs/87 pcs |
Accuracy | ≤0.5% (Deviation of D50 on national standard sample) |
Repeatability | ≤0.5% (Deviation of D50 on national standard sample) |
Laser | Semi conductor Laser λ= 636.5nm, p>2mW Service time>25000 hour |
Wet dispersion | Ultrasonic | Frequency:40KHz Power:35W, Time: ≥1S |
Agitator | Revolutions Speed: 0-3000RPM (Adjustable) |
Circulation | Rated Flow:8L/min Rated Power:10W |
Sample tank | Volume: 350mL |
Operation mode | Manual and Full automatic |
Optical alignment system | Full automatic optical path alignment system |
Software function | Analysis mode | Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc. |
Statistic Method | Volume Distribution, Quantity Distribution |
Statistic Comparison | Several Testing Results of samples Different batches of samples testing result, Samples before and after processing, Test result of samples in different time. |
User-defined Analysis | Figure out percentage according to the particle size Figure out particle size according to the percentage Figure out percentage according to the particle size range Meet demands of representation of particle test in different industries |
Test Report | Word, Excel,Photo( Bmp), Text etc |
Multiple-language Support | Multiple language Support |
Intelligent operation | Automatically control water inflow, dispersion,test and analysis.Better Repeatability after remove human-factor |
Report Items | Particle size distribution table&graph, average diameter, Median diameter, SSA, etc. |
Testing speed | <2min/time (including all the procedures) |
Running temperature | 15 ℃ -35 ℃ |
Humidity | <85% |
Outer dimension | L85cm*W39cm*H45cm |
Net weight | 40Kg |
Winner2005A is widely used for cement, ceramic, medicine, dope, dye, padding, chemical products, catalyst, braize, dust, additive,pesticide, explosive, graphite, photosensitive material, fuel, metal and nonmetal powder, calcium carbonate, kaolin and other powder materials.
Company Profile
Jinan Winner Particle Instrument Co., Ltd. have have been specialized in particle size analyzer for more than 30 years, since we undertake National Science Project-particle size analyzer development in 1985. We are the 1st manufacturer to produce Nano-particle size analyzer in China. Our particle size analyzer will enable you understand materials well, and save your time and cost. Reliable data enables scientists, researchers and engineers to evolve formulations and processes with confidence. Our products guide research and product development, manage and control manufacturing quality, and optimize output.By now, We have Laser Particle size analyzer, Image particle size analyzer, Spray particle size analyzer, particles counter and Nano-particles size analyzer and so on. We are dedicated to offer you the best particle size analysis solution. Your satisfaction is our eternal target!
Quality Assurance
1. Strictly conforming to ISO9001-2000 quality management system.
2. Strict control from purchasing materials, process inspection to final particle size distribution test.3. QC department to execute quality control regulations.
4.Only qualified components will be assembled and total laser particle size analyzer must be inspected completely before sale.
5.Laser particle size analyzer will be processed preventing -shake test before delivery.
After Sale Service
1.Operation demo video CD will be offered.
2. Offer free-training service.
3. The quality assurance date is 1 year since finishing payment, Technology support will be provided for life. And after that, we will collect the cost if provide repair accessories.
4. Maintenance for equipment failure caused by improper handling (appropriate cost will be collected).
5. We offer the components with favorable price and perdurable maintenance.
FAQ
Purchase laser particle size analyzer need know points:
(1) What materials need test?
If suspension/emulsion, must choose liquid dispersion particle size analyzer, and some materials are also reacted with water, so need liquid dispersion particle size analyzer also. Generally, cement, metal powders and pharamcy materials need dry dispersion model particle size analzyer.
(2) What size range need test?
By now, Based on MIE scattering, laser particle size analyzer can test the particle range is 0.01um-2000um.
If materials range is not so wide, for example, 10um-20um, smaller range of particle size distributon choose closer range model will be preciser, no need to buy large range model.
(3) What is dispersion media?
For liquid model, in order that sample can disperse well and circualte in the laser particle size analyzer, generally we need use water, alochol or organic solvent as dispersion media.For dry dispersion model, just use compressed air as dispersion media.In the current market, Dry laser particle size analyzer cost is higher than liquid dispersion models, so if can test well, liquid model is better.
More questions, please contact us, we will offer you the best suitable laser particle size analyzer for you!