Winner 901 Photon Correlation DLS Nanoparticle Size and Zeta Potential Analyzer
Winner 901 Photon Correlation DLS Nanoparticle Size and Zeta Potential Analyzer

Winner 901 Photon Correlation DLS Nanoparticle Size and Zeta Potential Analyzer

44998 - 49998 /Set

Min.Order:1 Set

Supply Ability:
500 Set / Sets per Month
Port:
Qingdao/kangkong
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other

Quick Details View All >

Brand Name:
winner
Place of Origin:
China
Model Number:
Winner 901

Jinan Winner Particle Instrument Stock co.itd

Business license
Business Type: Manufacturer
Main Products: Laser Diffraction Particle Size Analyzer ,Nano Particle Size Analyzer ,Spray Particle Size Analyzer ,Particle Image Analyzer for particle characterization

Product Details

Products Description

Winner901 Nano Particle Size and Potential Analyzer is a new high-end dynamic light scattering particle size analyzer product launched by Winner Particle Instrument Co., Ltd. which has dual testing capabilities of zeta potential and nano-particle size.


Specification

Model No.
Winner901
Executive standard
 GB/T 19627-2005/ISO 13321:1996 ;GB/T 29022-2012/ISO 22412:2008
Function
Size, Zeta potential, Molecular weight
Measure range
1-10000nm (reference to sample)
-500mV — +500mV
Concentration range
0.1mg/ml--100mg/ml (reference to sample)
Electrophoretic mobility range
> ±20μm.cm/V.s
Highest conductivity
200mS/cm (reference to sample)
Accuracy error
<1% (National standard sample D50 value)
<10% (Standard sample)
Repeatability error
<1% (National standard sample D50 value)
<10%(Standard sample)
Laser Source
Semiconductor laser λ= 635nm,P=1-40mw (adjustable)
Detector
Photomultiplier tube
Scattering angle
90°
18°
Sample cell volume
10mm*10mm*40mm, 1--4mL
10mm*10mm*60mm, 1mL
Temperate range
5-45℃
Temperature control accuracy
0.1℃
Test speed
<5 Min
Digital correlator
Model
HA1024
HA1024
Auto-correlation channels
892
892
Baseline channel
4

Physical channels
5000

Unit delay time
1µs-10ms(adjustable)
1µs-10ms(adjustable)
Outer dimension
560mm*450mm*300mm
N.W.
20Kg
Product details

 Winner901 uses electrophoretic light scattering technology to measure zeta potential and obtain isoelectric point, and uses static light Scattering (SLS) techniques measure molecular weight. Compared with other instruments of the same type at home and abroad, it has significant advantages, and can be used in various experiments in conjunction with the laser particle size distribution analyzer.


Application

Winner901 Nano Particle Size and Potential Analyzer has both zeta potential and nano particle size analysis and testing functions. It is suitable for particle size and surface potential measurement of a variety of different nanoemulsions, suspension colloids, etc. It can be widely used in fine chemical industry nanomaterials, R&D and production quality control of surfactants, oligomers, etc. It is also a product development and quality control testing instrument for inks, pharmaceutical preparations and other industries.


Main Features

Test principle:
 Using the principle of electrophoretic light scattering and photon correlation spectroscopy, the size of particle Zeta potential was determined according to the electrophoretic movement speed of particles in liquid. The population velocity of the electrophoretic motion of the particles, and the amount of Doppler shift of the scattered light caused by the laser irradiation of these particles, varies. Photon correlation spectroscopy analyzes the size of particle Zeta potential according to the frequency shift.  
Ultra-high-speed data acquisition:
The core component of the instrument is through the HA1024 digital correlator, which can complete the collection of electrophoretic scattered light intensity and the calculation of the auto-correlation function in real time, so as to effectively reflect the information of the electrophoretic movement speed of the particles and lay the foundation for the accuracy of the Zeta potential test results.  
High sensitivity signal-to-noise ratio:
Using professional-grade high-performance photomultiplier tubes, it has extremely high sensitivity and signal-to-noise ratio to photon signals.
High-precision constant temperature control:
 Using semiconductor temperature control technology, the temperature control accuracy is as high as 0.1 °C, so that the sample is always in a constant temperature state during the whole test process, avoiding the test deviation caused by the change of liquid viscosity and Brownian motion caused by temperature changes, and ensuring the accuracy and stability of the test results.
Stable optical path system:
 The optical path system constructed by the optical frequency shifting device and the optical fiber coupling technology makes the detection system not only small in size, but also has strong anti-interference ability, thus ensuring the stability of the test.


Packaging and delivery

Winner particle testing equipment is Wooden box package.
We would ship machine by DHL, FeDex, China express, by sea and by air.


FAQ

Purchase laser particle size analyzer need know points:
(1) What materials need test?
If suspension/emulsion, must choose liquid dispersion particle size analyzer, and some materials are also reacted with water, so
need liquid dispersion particle size analyzer also. Generally, cement, metal powders and pharamcy materials need dry dispersion
model particle size analzyer.
(2) What size range need test?
By now, Based on MIE scattering, laser particle size analyzer can test the particle range is 0.01um-2000um.
If materials range is not so wide, for example, 10um-20um, smaller range of particle size distributon choose closer range model
will be preciser, no need to buy large range model.
(3) What is dispersion media?
For liquid model, in order that sample can disperse well and circualte in the laser particle size analyzer, generally we need use
water, alochol or organic solvent as dispersion media.For dry dispersion model, just use compressed air as dispersion media.In the
current market, Dry laser particle size analyzer cost is higher than liquid dispersion models, so if can test well, liquid model
is better.
More questions, please contact us, we will offer you the best suitable laser particle size analyzer for you!



Contact Supplier

Ms. Chat Now

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Measuring & Analysing Instrument Stocks
Categories
Hi~