60WKS-CE240/22PB
USD $1113 - $2023 /Piece
Min.Order:1 Piece
Temporal Ming sheng automation equipment co., LTD
Brand: KOLLMORGEN
Type:60WKS-CE240/22PB
Origin: the United States
Warranty: 365 days
Colour: new/used
Shipping method: Courier delivery
The CI865 is powered from the processor unit via the CEX-Bus and requires no additional external power source. No field device is powered from the CI865. Use the following procedure to connect the ControlNet to the BNC connector of the I/O systems and the CI865 module. For more information see Satt I/O Interface for AC 800M (3BSE042821*). The BNC connector is located: • Rack I/O - at the rear of the 200-RACN module. • Series 200 I/O - at the front of the 200-ACN module. • CI865 - at the front of the CI865 module. 1. Select a suitable location for the tap within one meter from the ControlNet BNC connector. When selecting the tap location, keep in mind the routing of the drop and trunk cables. They should not be routed close to high-voltage cables. Avoid bending the trunk cable too much. 2. The tap can be mounted in various ways, for example using a DIN rail or screwed into a suitable structure. Even if the tap is not mounted on a DIN rail, the universal mounting bracket should be used to avoid galvanic connection to a conducting structure. 3. Connect the tap drop cable to the BNC connector. Before starting up the system, all ControlNet cable connections should be tested. Check the pulling strength of applied connectors. 4. Define the network node address: – Rack I/O - by turning the two switches (x10 and x1) on front of the 200- RACN module to the correct position. A node address in the range 02-99 should be selected for the 200-RACNs. – Series 200 I/O - by clicking the push button switches on the front of the 200-ACN module. A node address in the range 02-99 should be selected for the 200-ACNs. – CI865 - The node address is fixed to 01.
The CI867 is powered from the processor unit via the CEX-Bus and no additional external power source is required. Use the following procedure to install the CI867/TP867: 1. Mount the unit onto the DIN-rail, see Mounting AC 800M Units onto DINRailon page 65 and Installing the PM86x/TP830 Processor Unit in Single Configurationon page 78. 2. Connect the 10/100Mbps Ethernet twisted pair cable to the CH1 connector on the baseplate. 3. Connect the other end of the Ethernet cable to a Fast Ethernet network via standard Ethernet components. 4. Connect the 10Mbps Ethernet twisted pair cable to the CH2 connector on the baseplate. 5. Connect the other end of the Ethernet cable to a Ethernet network via standard Ethernet components. Ethernet Twisted Pair Connection The Fast 10/100 Mbps Ethernet twisted pair is connected via the RJ45 connector (CH1) located on TP867. The slower 10 Mbps Ethernet twisted pair is connected via the RJ45 connector (CH2) located on TP867