HIMA EABT3 B9302

HIMA EABT3 B9302

USD $1150 - $2050 /Piece

Min.Order:1 Piece

Supply Ability:
120 Piece / Pieces per Month
Payment Terms:
T/T
Delivery Detail:
1 days

Quick Details View All >

Brand Name:
HIMA
Place of Origin:
China
Model Number:
EABT3 B9302

Temporal Ming sheng automation equipment co., LTD

Business license
Main Products: ABB、GE、MOTOROLA、BENTLY、EMERSON、HIMA、TRICONEX

Product Details

Brand:HIMA

Type:EABT3 B9302

Origin: the United States

Warranty: 365 days

Colour: new/used

Shipping method: Courier delivery

Spare parts spare parts, the main DCS control system of PLC system and the robot system spare parts,

Brand advantage: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts

The CI862 is in the process of being restarted or configured. Allow time for this to finalize. If the condition persists, and all other units on the CEXbus have non-illuminated LEDs: • Check that a valid HW configuration including the CI862 is downloaded to the controller. • Check the CEX-bus fuse inside the PM8xx processor unit. • Initiate a reset signal (INIT) from the PM8xx processor unit. • Replace the CI862. F(ault) LED is ON Check that the CI862 is in the process of being restarted. Allow time for this to finalize. Check that there is no configuration fault reported from CI862 in CBM.If the status remains, initiate a reset signal (INIT) from the PM8xx processor unit. If the status still remains after the reset replace the CI862. COMM ERROR LED is ON Field Bus Communication Error from the µGenie slave module. PRIM LED is OFF The CI862 is in the process of being restarted or configured. Allow time for this to finalize. Check that there is no configuration fault reported from CI862 in CBM. DUAL LED is OFF on both CI862’s The CI862 is in the process of being restarted or configured. Allow time for this to finalize. Check that the redundancy for this module is set within CBM and the configuration is downloaded.

The CI865 unit is in the process of being configured. Allow time for this to finalize. If the condition persists, and no other unit LED on the CEX-Bus is lit: • Check that a valid HW configuration including the CI865 is downloaded to the controller. • Check the CEX-Bus fuse inside the PM8xx processor unit • Initiate a reset signal (INIT) from the PM8xx processor unit • Replace the CI865 unit

Contact Supplier

Ms. Chat Now

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Other Electrical Equipment
Categories
Hi~