HIMA F7553
USD $1151 - $2051 /Piece
Min.Order:1 Piece
Temporal Ming sheng automation equipment co., LTD
Brand:HIMA
Type:F7553
Origin: the United States
Warranty: 365 days
Colour: new/used
Shipping method: Courier delivery
Spare parts spare parts, the main DCS control system of PLC system and the robot system spare parts,
Brand advantage: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts
The yellow DUAL LED is OFF when any of the following conditions are met: • CI872 is run in single configuration. • CI872 is run in redundant configuration, but it acts as a backup module. All LED's are OFF Possible Cause 1: Difference in the CI872 position in the Hardware Tree (in the Control Builder) as compared to the CI872 position on the CEX-Bus. Corrective Action 1: Check and correct the position of CI872 module in the Hardware Tree in accordance with the position on CEX-Bus, or vice-versa. Possible Cause 2: The CI872 module is hot inserted and the configuration is not downloaded to the controller. Corrective Action 2: Ensure that the module is configured in the Hardware Tree (in the Control Builder) for that position, and that the configuration is downloaded to controller. Possible Cause 3: The CI872 is just hot inserted and it is in the process of configuration. Corrective Action 3: Allow time for the module to initialize.
Possible Cause 1: MTMConnect and/or MTMReadCyc and/or MTMDefCyc are disabled. Corrective Action 1: Enable MTMConnect, MTMReadCyc, and MTMDefCyc function blocks. Possible Cause 2: MTMConnect and/or MTMReadCyc and/or MTMDefCyc function blocks show a bad status. Corrective Action 2: Check the reason for the bad status (see the status codes for MTMCommLib in the Online Help), and take the appropriate corrective action for the bad status. Possible Cause 3: The value for the Channel parameter in the MTMConnect function block is not in accordance with the position of the CI872 module in the Hardware Tree. Corrective Action 3: Ensure that the value of the Channel parameter in the function block is in accordance with the position of the CI872 module in the Hardware Tree. Corrective Action 4: If the condition persists even after performing corrective actions 1 to 3, then hot remove and hot insert the CI872 module on the CEX-Bus and allow time for the module to initialize. If the corrective action is to replace the faulty CI872 module, replace it with another CI872 module which has the same version of hardware and firmware. CI872 supports hot swap