220v Solenoid Valve , NC Wire Lead Type Brass / Stainless Steel Electric Water Valve
Negotiable /Set
Min.Order:1 Set
Solenoid Operated Directional Valves For Hydraulic System Flow Direction Control
Vickers Solenoid Valves , Vickers Directional Valve Dg4v3 Dg4v5 Series Coil Insulation Class H
Brass Solenoid Valves , AC220V 12V DC Normally Close 2 Way Solenoid Valves
DG4V3 Vickers Hydraulic Solenoid Valves , 1/4\" Port Solenoid Directional Valve
Pilot Operated Vickers Solenoid Hydraulic Directional Valves For Control Flow On Off
200 Bar High Pressure Solenoid Valve , Stainless Steel Solenoid Valves Air / Water
Brass or stainless steel water solenoid valve 1/4 inch 220V AC 2W025-08 NC Wire lead type
Specification
It is direct action type two-position two-way solenoid valve. It adopts the diaphragm seal structure,with zero differential pressure starting function,handsome shape,and large flow. It is a switch element most normally used in modern industrial pipeline.
Start working at differential pressure, the UW series valve has a completely range of solenoid valves from 1/8" to 2". UW series valve is among the oldest history valves, we have stainless steel valve and brass valve for your reference, both of SS valve and brass valve can be normal close valve and normal open valve. This series solenoid valves are most popular valves used for many conditions especially in the water treatment system.
Model NO. | 2w-025-06 | 2w-025-08 | 2w-040-10 | 2w-160-10 | 2w-160-15 | 2w-200-20 | 2w-250-20 | 2w-320-32 | 2w-400-40 | 2w-500-50 |
Pipe size | 1/8” | 1/4” | 3/8” | 1/2” | 3/4” | 1” | 1 1/4“ | 1 1/2” | 2” | |
Orifce size | 2.5mm | 4mm | 4mm | 16mm | 16mm | 20mm | 25mm | 32mm | 40mm | 50mm |
CV valve | 0.23 | 0.6 | 4.8 | 4.8 | 7.6 | 12 | 24 | 29 | 48 | |
fuild | Air, water, ol, the neutral gas,liquid | |||||||||
Service voltage | AC380V,AC220V,AC110V,AC24V,DC24V, (allow)±10% | |||||||||
Operating | Direct acting | Type | Normally closed | |||||||
Body Material | Brass | viscosity | (Below)20CST | |||||||
Working pressure | Water, air;0-10kgf/m2 ;oil:0-7kgf/m2 | |||||||||
Material of seal | Standard: below 80 °C fuild temperature use NBR below 120°C use EPDM below 150 °C use VITON |
Maintenance instructions:
1. attention to check the use of components, in the transport process is damaged, and then install the use of.
2. When installing, please note that the gas flow direction and the takeover are correct.
3. when using, please strictly comply with the technical requirements, such as the operating voltage, operating frequency, working pressure, the use of temperature, the whole machine debugging, it is recommended to use a manual device debugging, and then through power debugging.
4. Please pay attention to dust, it is recommended to install the exhaust port or muffler muffler throttle.
5. When connecting pipe, pay attention to only release the strap around the joint may not exceed the end face of the tooth, and pay attention to the elimination of pipe fittings, metal particles inside the pipe, dust and oil, etc