Delivery Time:6 working days
Waterproof Industrial Single Point Load Cell Weighing Sensor 100 kg for Retail Scales
Quick Detail:
Model: LC1760
Features:
Capacities(kg):100kg - 750kg High comprehensive precision, high stability Compact structure, easy to install Small size with profile Anodized aluminum alloy The four deviation has been adjusted Recommended Platform size: 600mm×600mmDescription:
LC1760 is a kind of Single Point Load Cell, It is made of aluminum alloy, its surface must be anodized, and the degree of protection reaches to IP65, which has the function of waterproof and moisture-proof, so it is available for the humid and corrosion environment.
LC1760 load cell is available in the capacities 100kg to 750kg, its structure is very compact, so it is very easy to install, the four deviation has been adjusted, which can keep a balance of each point of the scales. Its recommended platform size is 600mm×600mm, It is a cost-effective load cell for platform scales (single load cell), LC1760 is designed for electronic scales and platform scales where only one load cell can be used and low profile is required. The design is most suitable for mass production operations, for example, it can be applied for packaging machines, Retail Scales, Counting Scales, Electronic Scales Low profile platform scales, Chemical, Industries of Foods, Pharmaceuticals, which has huge important on weighing and control.
Applications:
Be suitable for the fields of Packaging Scales, Retail Scales, Counting Scales, Electronic Scales, Low profile platform scales, Chemical, Industries of Foods, Pharmaceuticals and other weighing systems, which has huge important on weighing and control.
Specifications:
Rated Load |
kg |
100, 200, 300, 500, 750 |
Recommended Platform Size |
mm |
600×600 |
Rated Output |
mV/V |
2.0±0.2 |
Zero Balance |
%R.O. |
±1 |
Comprehensive Error |
%R.O. |
±0.02 |
Non-linearity |
%R.O. |
±0.02 |
Hysteresis |
%R.O. |
±0.02 |
Repeatability |
%R.O. |
±0.02 |
Creep/30min |
%R.O. |
±0.02 |
Compensated temp. Range |
℃ |
-10...+40 |
Operating temp. Range |
℃ |
-20...+70 |
Temp.effect/10℃ on span |
%R.O./10℃ |
±0.02 |
Temp.effect/10℃ on zero |
%R.O./10℃ |
±0.02 |
Recommended excitation voltage |
VDC |
10 |
Maximum excitation voltage |
VDC |
15 |
Input impedance |
Ω |
410±10 |
Output impedance |
Ω |
350±3 |
Insulation resistance |
MΩ |
>5000 |
Safe overload |
%R.C. |
150 |
Ultimate overload |
%R.C. |
200 |