Tension Sensor High Capacity Tension Load Cells / Miniature Transducer with 6m Cable 20 Ton
Negotiable /Piece
Min.Order:1 Piece
Lascaux Microelectronic Device (Tianjin) Co.,Ltd,
Waterproof Tension Load Cells Resistance Sensor for Weighing Scale 300 Kg 500 Kg
Compact Tension Load Cells / Sensor Load Cell for Digital Amplifiers 100 kg - 500 kg
Anodized Aluminum Alloy Amplifier Tensile Load Cell With High Precision 0.05kg - 50 Kg
Moisture Proof Miniature Strain Gauge Load Cell / Compact Single Load Cell for Tension Measurement
10 Ton / 20 Ton Column Compression Load Cells for Silo or Hopper , High Accuracy
High Precision Double Ended Shear Beam Load Cell for Silo / Hopper / Truck scales 10 Ton - 50 Ton
Tension Sensor High Capacity Tension Load Cells / Miniature Transducer with 6m Cable
Quick Detail:
Model:RL
Features:
1. Capacities (t):2 to 20
2. Resistance strain measurement methods
3. High comprehensive precision, high stability
4. Compact structure, easy to install, wide application range
5. Removable, rugged, durable in use
6. Quick installation or removal via compact sensing head design
7. The maximum tension reaches 500ton
Description:
RL series are a kind of tension sensor, it is made of Alloy steel, nickel plating, The type adopt resistance strain measurement methods, high accuracy rotational, high stability, its structure is very compact, durable in use, it is mainly suitable for the measurement of wire, composite materials and familiar products.
RL is available in the capacities 2t to20t, very compact, RL series is ideal for new and existing winches to enable line tension, speed, and payout monitoring–key variables for offshore mooring applications, towing, for ensuring the safety of oceanographic payloads.
These models feature a rugged, compact design, high accuracy rotational and force sensors, and easy setup via an instrumented, and removable, center sheave, wire rope diameters up to 4.5 inches, single load cell can be matched with weighing indicator, converting what you want to, because the load cell itself output is mill volt (MV), it has to need an amplifier switch voltage or current.
It is used to measure the online tension, including wire, cables and other familiar products.
Applications:
It is used to measure the online tension, including wire, cables and other familiar products.
Specifications:
Rated Load |
kg |
2, 5, 10, 15, 20 |
Rated Output |
mV/V |
1.2-1.5mV/V |
Zero Balance |
%R.O. |
≤±2 |
Comprehensive Error |
%R.O. |
<3 |
Non-linearity |
%R.O. |
<±5 |
Hysteresis |
%R.O. |
<±0.5 |
Repeatability |
%R.O. |
<±0.5 |
Compensated temp. Range |
℃ |
-10~+40 |
Operating temp. Range |
℃ |
-20~+70 |
Temp.effect/10℃ on span |
%R.O./10 ℃ |
±0.02 |
Temp.effect/10℃ on zero |
%R.O./10 ℃ |
±0.02 |
Recommended excitation voltage |
VDC |
5-10 |
Maximum excitation voltage |
VDC |
15 |
Input impedance |
Ω |
380±10 |
Output impedance |
Ω |
350±3 |
Insulation resistance |
MΩ |
>3000 |
Safe overload |
%R.C. |
150 |
Ultimate overload |
%R.C. |
200 |
Material |
Alloy steel |
|
Degree of protection |
IP65 |
|