Small Low Capacity Single Point Load Cell for Electronic Balance 0.3kg - 5 kg
Negotiable /Piece
Min.Order:1 Piece
Lascaux Microelectronic Device (Tianjin) Co.,Ltd,
IP68 Single Point Load Cell / Strain Gage Load Cell for Weighing System 4 kg - 20 kg
Tension Compression Miniature Load Cells for Kitchen Scale , Static and Dynamic 100 Kg
IP68 Waterproof Column Tension and Compression Load Cell Resistance Sensor 30 Ton 50 Ton
200 kg Multi Axis Tension and Compression Load Cell Low Profile for Testing Machine
Aluminum IP65 Small Tension and Compression Load Cell for Weighing Scale 1 Ton , 5 Ton
High Precision Tension and Compression Load Cell for Electronic Truck Scale 5 Ton , 450 KN
Small Low Capacity Single Point Load Cell for Electronic Balance 0.3kg - 5 kg
Quick Detail:
Model: LC7012
Features:
Capacities(kg):0.3kg……5kg High comprehensive precision, high stability Compact structure, easy to install Small size with profile Anodized aluminum alloy The four deviation has been adjusted Recommended Platform size: 200mm×200mmDescription:
LC7012 is a kind of Single Point Load Cell, It is made of aluminum alloy, and its surface must be anodized. The protection level reaches to IP65, which provide excellent protection against moisture ingression.
LC7012 load cell is available in the capacities 0.3kg to 5kg, its structure is very compact, very light, small size with profile, and easy to install, has the function of high stability, LC7012 is designed for electronic scales and platform scales where only one load cell can be used and low profile is required. Recommended platform size is 200mm×200mm, the design is most suitable for mass production operations.
LC7012 can be used for Low profile platform scales (If choosing the suitable attachment), Packaging Scales, Retail Scales, Counting Scales, Electronic Scales, Chemical, Industries of Foods, Pharmaceuticals and other weighing systems.
Applications:
Be suitable for the fields of Packaging Scales, Retail Scales, Counting Scales, Electronic Scales, Low profile platform scales, Chemical, Industries of Foods, Pharmaceuticals, which has huge important on weighing and control.
Specifications:
Rated Load |
kg |
0.3, 0.5, 1, 2, 3, 5 |
Recommended Platform Size |
mm |
200×200 |
Rated Output |
mV/V |
1±0.2 |
Zero Balance |
%R.O. |
±1 |
Comprehensive Error |
%R.O. |
±0.02 |
Non-linearity |
%R.O. |
±0.02 |
Hysteresis |
%R.O. |
±0.02 |
Repeatability |
%R.O. |
±0.02 |
Creep/30min |
%R.O. |
±0.02 |
Compensated temp. Range |
℃ |
-10...+40 |
Operating temp. Range |
℃ |
-20...+70 |
Temp.effect/10℃ on span |
%R.O./10℃ |
±0.02 |
Temp.effect/10℃ on zero |
%R.O./10℃ |
±0.02 |
Recommended excitation voltage |
VDC |
10 |
Maximum excitation voltage |
VDC |
15 |
Input impedance |
Ω |
410±10 |
Output impedance |
Ω |
350±3 |
Insulation resistance |
MΩ |
>5000 |
Safe overload |
%R.C. |
150 |
Ultimate overload |
%R.C. |
200 |
Material |
Aluminum |
|
Degree of protection |