din rail switching power supply(DR-45-15)
Negotiable /Piece
Min.Order:10 Pieces
Zhejiang Lierd Relays Enterprise Co., Ltd.
AC to DC power supply/led power supply/ac power suuply/dc power suply (black cover)
60W 24V 2.5A single output power supply/cctv power supply/dc power supply S-60
24V power supply/din rail power supply/ac/dc power supply/adjustable power supply/led power supply
400W 48V signal ouput Power Supply/enclosed power supply/ac to dc power supply/meanwell power supply
Model | DR-45-5 | DR-45-12 | DR-45-15 | DR-45-24 |
DC output voltage | 5V | 12V | 15V | 24V |
Output voltage range(Note:2) | ±2% | ±1% | ±1% | ±1% |
Rated output current | 5A | 3.5A | 2.8A | 2A |
Output current range | 0-5A | 0-3.5A | 0-2.8A | 0-2A |
Wave and noise(Note:3) | 100mVp-p | 200mVp-p | 240mVp-p | 480mVp-p |
Inlet stability(Note:4) | ±1% | ±1% | ±1% | ±1% |
Load stability(Note:5) | ±1% | ±1% | ±1% | ±1% |
DC output power | 25W | 42W | 42W | 48W |
Efficiency | 72% | 77% | 77% | 80% |
Adjustable range for DC voltage | 4.75~5.5V | 10.8~13.2V% | 13.5~16.5V% | 21.6~26.4V |
AC input voltage range | 85~264VAC 47~63Hz;120~370VDC | |||
Input current | 1.5A/115V 0.75A/230V | |||
AC inrush current | Cold-start current 30A/115V 60A/230V | |||
Leakage current | <1mA/240VAC | |||
Overload protection | 105%~150% Type: pulsing hiccup shutdown Reset: tuto recovery | |||
Temperature coefficient | ±0.03%/°c(0~50°c) | |||
Setup, rise , hold up time | 800ms, 60ms, 50ms | |||
Vibration | 10~500Hz, 2G 10min,/1cycle, Period for 60min, Each axes | |||
Withstand voltage | Input and output internal: Input and encolsur: 1.5KvAC, Output and enclosure: 0.5KvAC | |||
Isolation resistance | Input and output internal: Input and enclosure, Output and enclosure:500VDC/100MΩ | |||
Working temperature and humidity | -10°c~+60°c(Refer to output derating curve), 20%~90%RH | |||
Overall dimension | 93×78×67mm | |||
Weight | 0.31Kgs | |||
Safety standards | Meet UL 1012 requiement (Not apply for the mark) | |||
EMC standards | Meet FCC PART 15 J Conduction class B | |||
Note: 1. The testing condition for the paramenter above is: 230VAC input, rated load, 25°c 70% RH. Temperatuer. 2. Error: include the setting error, line stability and load stability.(Note:5) 3. Wave test: adopting "A12" double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting. 4. Inler woltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage. 5. Load stability test: The load is from 0% to 100% |