12V 8.5A switching power suppply S-100-12
Negotiable /Piece
Min.Order:10 Pieces
Zhejiang Lierd Relays Enterprise Co., Ltd.
2. AC input power suitable for the world
3. High efficiency and low operation temperature
4. Soft-start current can reduce the AC input impact effeciticly
5. With short-circuit and overload protection
6. Compact size, light weight
7. 100% full-load burn-in test
8. Installed with EMI filter, minimum wave
Model | S-100-3 | S-100-5 | S-100-7.5 | S-100-12 | S-100-15 | S-100-24 | S-100-27 | S-100-48 |
DC output voltage | 3V | 5V | 7.5V | 125V | 15V | 24V | 27V | 48V |
Output voltage range(Note:2) | ±2% | ±2% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% |
Rated output current | 20A | 20A | 13.6A | 8.5A | 6.7A | 4.5A | 3.7A | 2A |
Output current range | 0-20A | 0-20A | 0-13.6A | 0-8.5A | 0-6.7A | 0-4.5A | 0-3.7A | 0-2A |
Wave and noise(Note:3) | 150mV | 150mV | 150mV | 150mV | 150mV | 150mV | 200mV | 240mV |
Inlet stability(Note:4) | ±0.5% | ±0.5% | ±0.5% | ±0.3% | ±0.3% | ±0.2% | ±0.2% | ±0.2% |
Load stability(Note:5) | ±1% | ±1% | ±0.5% | ±0.3% | ±0.3% | ±0.2% | ±0.3% | ±0.2% |
DC output power | 60W | 100W | 102W | 102W | 100.5W | 108W | 99.9W | 96W |
Efficiency | 70% | 78% | 81% | 81% | 81% | 84% | 84% | 84% |
Adjustable range for DC voltage | 2.85~3V | 4.75~5.5V | 6.75~8.25V | 10.8~13.2V | 13.5~16.5V | 21.6~26.4V | 26~32V | 43.2~52.8V |
Input current | 2.4A/115V 1.2A/230V | |||||||
AC inrush current | Cold-start current 30A/115V 60A/230V | |||||||
Leakage current | <1mA/240VAC | |||||||
Overload protection | 105%~150% | 150%~200% | 105%~150% | |||||
Type: Output shutdown Reset: Recycle AC ON/OFF | ||||||||
Temperature coefficient | ±0.03%/°c(0~50°c) | |||||||
Setup, rise , hold up time | 200ms,100ms, 30ms | |||||||
Vibration | 10~500Hz, 2G 10min,/1cycle, Period for 60min, Each axes | |||||||
Withstand voltage | Input and output internal: 1.5KvAC, Input and enclosure:1.5KvAC, Output and enclosure:0.5KvAC | |||||||
Working temperature and humidity | -10°c~+60°c(Refer to output derating curve), 20%~90%RH | |||||||
Weight | 0.65Kgs | |||||||
Safety standards | Meet UL 1012 requirementNot apply forr the mark | |||||||
EMC standards | Meet FCC PART 15 J Conduction class B | |||||||
Note: 1. The testing condition for the paramenter above is: 230VAC input, rated load, 25°c 70% RH. Temperatuer. 2. Error: include the setting error, line stability and load stability.(Note:5) 3. Wave test: adopting "A12" double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting. 4. Inlet woltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage. 5. Load stability test: The load is from 0% to 100% |