5V 50A single dc regulated power supply(S-320-5)
Model | S-320-5 | S-320-7.5 | S-320-12 | S-320-13.5 | S-320-15 | S-320-24 | S-320-27 | S-320-48 |
DC output voltage | 5V | 7.5V | 12V | 13.5V | 15V | 24V | 27V | 48V |
Output voltage range(Note:2) | ±2% | ±2% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% |
Rated output current | 50A | 36A | 25A | 22A | 20A | 12.5A | 11A | 6.5A |
Output current range | 0-50A | 0-36A | 0-25A | 0-22A | 0-20A | 0-12.5A | 0-11A | 0-6.5A |
Wave and noise(Note:3) | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 240mVp-p |
Inlet stability(Note:4) | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load stability(Note:5) | ±1% | ±1% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
DC output power | 250W | 270W | 300W | 297W | 300W | 300W | 297W | 312W |
Efficiency | 73% | 76% | 74% | 79% | 78% | 81% | 82% | 83% |
Adjustable range for DC voltage | 4.5~5.6V | 6~9V | 10~13.2V | 12~15V | 13.5~18V | 20~26.4V | 26~32V | 41~56V |
Input current | 6A/115V 3.5A/230V | |||||||
AC inrush current | 18A/115V 36A/230V | |||||||
Leakage current | <3.5mA/240VAC | |||||||
Overload protection | 105%~135% Type: pulsing hiccup shutdown Reset: auto recovery | |||||||
Over-voltage protection | 5.75~6.75V | 9.4~10.9V | 13.8~16.2V | 15.5~18.2V | 18~21V | 27.6~32.4V | 33.7~39.2V | 57.6~67.2V |
High-temperature protection | ERH3>=65~70°c Fan on, <=55~60°c Fan off,>=80~85°c, Cut off ouput(5~15V)~(24~48V) | |||||||
Setup, rise , hold up time | 2ms,20ms, 20ms | |||||||
Vibration | 10~500Hz, 2G 10min,/1cycle, Period for 60min, Each axes | |||||||
Withstand voltage | Input and output internal: 1.5KvAC, Input and enclosure:1.5KvAC, Output and enclosure:0.5KvAC | |||||||
Working temperature and humidity | -10°c~+60°c(Refer to output derating curve), 20%~90%RH | |||||||
Weight | 1.15Kgs | |||||||
Safety standards | Design refer to Ul 1950 | |||||||
EMC standards | Design refer to FCC Part 15J Part 15 J class A | |||||||
Note: 1. The testing condition for the paramenter above is: 230VAC input, rated load, 25°c 70% RH. Temperatuer. 2. Error: include the setting error, line stability and load stability.(Note:5) 3. Wave test: adopting "A12" double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting. 4. Inlet woltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage. 5. Load stability test: The load is from 0% to 100% |