24V 10.4A single switching power supply(S-250-24)

24V 10.4A single switching power supply(S-250-24)

Negotiable /Piece

Min.Order:10 Pieces

Supply Ability:
10000 Piece / Pieces per Month
Payment Terms:
Credit Card

Quick Details View All >

Place of Origin:
Zhejiang, China
Brand Name:
LIRRD
Model Number:
S-250-24
Output Power:
201 - 300W
Output Type:
Single
Input Voltage:
Other

Zhejiang Lierd Relays Enterprise Co., Ltd.

Business Type: Manufacturer,Trading Company
Wenzhou Zhejiang China
Main Products: electromagnetic relay ,solid state relay ,time relay ,relay base ,power supply

Product Details

Specifications

24V 10.4A single switching power supply(S-250-24)
CE certificate, better rediating effect
competitve price, high quality

24V 10.4A single switching power supply(S-250-24)

ModelS-250-12S-250-13.5S-250-15S-250-24S-250-27S-250-48
DC output voltage12V13.5V15V24V27V48V
Output voltage range(Note:2)±1%±1%±1%±1%±1%±1%
Rated output current20A18A16.6A10.4A9.2A5.2A
Output current range0-20A0-18A0-16.6A0-10.4A0-9.2A0-5.2A
Wave and noise(Note:3)150mVp-p150mVp-p150mVp-p150mVp-p150mVp-p150mVp-p
Inlet stability(Note:4)±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%
Load stability(Note:5)±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%
DC output power240W243W249W

249.6W

248.4W249.6W
Efficiency82%83%84%86%86%87%
Adjustable range for DC voltage10~13.2V12~15V13.5~18V20~26.4V26~32V41~56V
AC input voltage range88~132VAC/176~264VAC selected by switch  47~63Hz;
Input current6A/115V 3.5A/230V
AC inrush current20A/115V 40A/230V
Leakage current<3.5mA/240VAC
Overload protection105%~150% Type: pulsing hiccup shutdown Reset: tuto recovery
Temperature coefficient±0.03%/°c(0~50°c)
Setup, rise , hold up time2s, 20ms, 20ms
Vibration10~500Hz, 2G 10min,/1cycle, Period for 60min, Each axes
Withstand voltageInput and output internal: Input and encolsur: 1.5KvAC, Output and enclosure: 0.5KvAC
Isolation resistanceInput and output internal: Input and enclosure, Output and enclosure:500VDC/100MΩ
Working temperature and humidity -10°c~+60°c(Refer to output derating curve), 20%~90%RH
Overall dimension215×115×50mm
Weight1.15Kgs
Safety standardsDesign refer to UL 1950

Note:                                                                                                                                                                  1. The testing condition for the paramenter above is: 230VAC input, rated load, 25°c 70% RH. Temperatuer.                 

2. Error: include the setting error, line stability and load stability.(Note:5)                                                                 

3. Wave test: adopting "A12" double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting.             

4. Inler woltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage.                       

5. Load stability test: The load is from 0% to 100%

Contact Supplier

Ms. Ivy Cheng Chat Now
Telephone
86-577-6279 7377
Mobile
86 138 0686 3999
Fax
86-577-6279 7373
Address
No.6 Xinguang Road Zhenxing AVE ,Liushi Town Yueqing City Zhejiang Province China Zhejiang

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Power Supplies > Switching Power Supply
Categories
Hi~