60W 24V 2.5A single output power supply/cctv power supply/dc power supply S-60
Negotiable /Piece
Min.Order:10 Pieces
Zhejiang Lierd Relays Enterprise Co., Ltd.
1. 105oC Output capacitor
2. AC input power suitable for the world
3. High efficiency and low operation temperature
4. Soft-start current can reduce the AC input impact effeciticly
5. With short-circui and overload protection
6. Compact size, ligh weight
7. 100% full-load burn-in test
8. Installed with EMI filter, minimum wave
Model | S-60-5 | S-60-12 | S-60-15 | S-60-24 |
DC output voltage | 5V | 12V | 15V | 24V |
Output voltage rang(Note:2) | ±2% | ±1% | ±1% | ±1% |
Rated output current | 12A | 5A | 4A | 2.5A |
Output current range | 0-12A | 0-5A | 0-4A | 0-2.5A |
Wave and noise(Note:3) | 120mVp-p | 120mVp-p | 150mVp-p | 150mVp-p |
Inlet stability(Note:4) | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load stability(Note:5) | ±1% | ±0.5% | ±0.5% | ±0.5% |
DC output power | 60W | 60W | 60W | 40W |
Efficiency | 72% | 76% | 77% | 79% |
Adjustale range for DC voltage | +10,-5% | +10% | +10% | +10% |
Input current | 1.6A/115V 0.8A/230V | |||
AC Inrush current | Cold-start current 30A/115V 60A/230V | |||
Leakage current | <3.5mA/240VAC | |||
Overload protection | 105%~150% Type: pulsing hiccup shutdown Reset: auto recovery | |||
Temperature coefficient | ±0.03%/°c(0~50°c) | |||
Setup, rise, hold up time | 800ms, 50ms, 10ms/115V 300ms, 50ms, 80ms/230VAC | |||
Vibration | 10-500Hz, 2G 10min,/1cycle, Period for 60min, Each axes | |||
Withstand voltage | Input and output internal 1.5KVAC, Input and enclosuer 1.5 KVAC, Output and enclosuer 0.5 KVAC | |||
Working temperature and humidity | -10°c~+60°c Refer to output derating curve, 20%~90% RH | |||
Store temperature and humidity | -20°c~+85°c, 10%~95%RH | |||
Weight | 0.5Kgs | |||
Satety standards | UL 1012 TUV EN6050(IEC, UL 1950) Approved | |||
EMC standards | CISPR22(EN55022), IEC801-2,3,4 IEC555-2 Verfication | |||
Note: 1. The testing condition for the parameter above is: 230VAC input, rated load, 25°c 70% RH.Temperatuer. 2. Error: include the setting error, line stability and load stability.(Note:5). 3.Wave test: adopting "A12" double wire for 20 MHz, and 0.1 UF&47UF capacitor short-circuit for interrupting. 4. Inlet voltage stability test: wht is overload, the lowest voltage of inlet is up to the highest voltage. 5. Load stability test: The load is from 0% to 100% |