40W Battery Charger Power Supply(switching power supply)
Negotiable /Piece
Min.Order:10 Pieces
Yueqing Ledisen Imp. & Exp. Co., Ltd.
40W Battery Charger Power Supply(switching power supply)
Features:
Universal AC input / Full range
Protections:Short circuit/Over load/Over voltage
Battery low protections
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 45KHz
MODEL | AD-40A | AD-40B | |||
---|---|---|---|---|---|
OUTPUT | DC VOLTAGE | 13.8V | 13.4V | 27.6V | 26.5V |
RATED CURRENT | 2.9A | 0.23A | 1.4A | 0.16A | |
CURRENT RANGE | 0 ~ 3A | ---------- | 0 ~ 1.5A | ---------- | |
RATED POWER | 43.1W | 42.88W | |||
RIPPLE & NOISE (max.) Note.2 | 50mVp-p | ---------- | 100mVp-p | ---------- | |
VOLTAGE ADJ. RANGE | CH1:12 ~ 14.5V | CH1:24 ~ 29V | |||
VOLTAGE TOLERANCE Note.3 | ±1.0% | ---------- | ±1.0% | ---------- | |
LINE REGULATION | ±0.5% | ---------- | ±0.5% | ---------- | |
LOAD REGULATION | ±0.5% | ---------- | ±0.5% | ---------- | |
SETUP, RISE, HOLD TIME | 800ms,50ms, 20ms/230VAC 1600ms,50ms, 16ms/115VAC at full load | ||||
INPUT | VOLTAGE RANGE | 85 ~ 264VAC 240 ~ 370VDC | |||
FREQUENCY RANGE | 47 ~ 63Hz | ||||
EFFICIENCY (Typ.) | 70% | 73% | |||
AC CURRENT | 1.2A/115VAC 0.8A/230VAC | ||||
INRUSH CURRENT (max.) | COLD START 20A/115VAC 40A/230VAC | ||||
LEAKAGE CURRENT | <0.7mA / 240VAC | ||||
PROTECTION | OVERLOAD | 105 ~ 150% rated output power. | |||
Protection type: Hiccup mode, recovers automatically after fault condition is removed | |||||
OVER VOLTAGE | CH1:14.49 ~ 18.63V | CH1:28.98 ~ 37.26V | |||
Protection type: Hiccup mode, recovers automatically after fault condition is removed | |||||
FUNCTION | DC ALARM SIGNAL(OPTIONAL) | AC fail CN1 PIN2 | |||
Battery low under charge voltage 82.5% 2% CN1 PIN1 | |||||
Normal 0.8V max. Abnormal 5V 0.5V | |||||
ENVIRONMENT | WORKING TEMP. | -10 ~ +60ºC (Refer to output load derating curve) | |||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||
STORAGE TEMP., HUMIDITY | -20 ~ +85ºC , 10 ~ 95% RH | ||||
TEMP. COEFFICIENT | ±0.03%/ºC (0 ~ 50ºC) on CH1 output | ||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | ||||
SAFETY & EMC | SAFETY STANDARDS | Design refer to UL60950-1, TUV EN60950-1 | |||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | ||||
EMI CONDUCTION & RADIATION | Compliance to EN55022 (CISPR22) Class B | ||||
HARMONIC CURRENT | Compliance to EN61000-3-2,-3 | ||||
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024,Light industry level, criteria A | ||||
OTHERS | MTBF | 302.1K hrs min. MIL-HDBK-217F (25ºC) | |||
DIMENSION | 129*98*38mm (L*W*H) | ||||
PACKING | 0.412Kg; 45pcs/20.43Kg/0.0326CMB | ||||
NOTE | 1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation. |