Integrated load table
Negotiable /Set
Min.Order:1 Set
SaiRui(GZ) test equipment CO.,LTD
Product characteristics of [Integrated load table]
1. Meet the requirements of GB16915.1-2014,GB2099.1-2015,GB15092.1-2010 standard;
2. Load output mode: resistive load, inductive load and fluorescent lamp capacitive load;
3. The parameters of voltage, current and power factor are displayed by digital meter.
4. A combination of multiple resistors and adjustable reactance is used to form resistive load and inductive load;
5. Capacitive load A and capacitive load B are composed of fixed capacitance and inductance.
6. Heat dissipation mode: air cooling;
7. It has the function of over-current, over-voltage and over-temperature protection;
8. Non-standard customization can be made according to the customer's needs.
Product introduction of [Integrated load table]
The 8120B integrated load test-bed is composed of a control cabinet and a resistive load cabinet, which can constitute two load modes, resistive and capacitive, and meet the requirements of GB15092.1-2010 (equivalent IEC61058-1:2008) standard.
Technical parameters of [Integrated load table] (non-customizable)
1. Test voltage: AC100V~250V, power supply frequency;
2. Accuracy of voltage digital display: ±3% ±3 words;
3. Resistive load current: a set of resistive load output current 0.5A~10A arbitrary setting resistive load total power is 10kV;
4. The accuracy of digital current display: ±3% ±3 words;
5. Capacitive load current;
6. Steady-state current: 0.5A~10A arbitrary setting;
7. Surge peak current: 5A~120A arbitrary setting;
8. Measuring surge peak current mode: using storage oscilloscope (Tecker TDS1002);
9. Measurement accuracy: ±10%;
10. Rectifier mode: bridge type rectification;
11.C × R2 = 2500 μ s, ±10%;
12. Operation test times: 0 ~ 999999, arbitrary setting, when the setting value is reached, cut off the sample power supply;
13. Over-current protection and over-voltage protection and over-temperature protection;
14. Power supply: 220 V ±5%, 50 Hz / 60 Hz.
Maintenance and regular maintenance of [Integrated load table]
Maintenance:
To prevent the occurrence of electric shock, do not lift the cover of the instrument. All parts inside the instrument need not be maintained by the user. If there is an abnormal condition in the instrument, please ask for maintenance from my laboratory. the attached lines and block diagrams are for reference only.
Regular maintenance:
At least once a year, the AC power supply and relevant accessories of input power line shall be carefully checked and checked to protect the safety of the user and the accuracy of the instrument.
For more information about products, please contact us and visit the company.