Meanwell 15V switching power supply/100W Single Output Switching power supply/15v switching power supply unit
USD $1 - $10 /Piece
Min.Order:10 Pieces
Hangzhou Nuohan Electronics Co., Ltd.
MODEL | LPS-100-15 | |
OUTPUT | DC VOLTAGE | 15V |
RATED CURRENT | 6.7A | |
CURRENT RANGE | 0 ~ 6.7A | |
RATED POWER | 100.5W | |
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | |
VOLTAGE ADJ. RANGE | 13.5 ~ 18V | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | |
LINE REGULATION | ±0.5% | |
LOAD REGULATION | ±1.5% | |
SETUP, RISE TIME | 800ms, 50ms/230VAC 1200ms, 50ms/115VAC at full load | |
HOLD UP TIME (Typ.) | 20ms/230VAC 20ms/115VAC at full load | |
INPUT | VOLTAGE RANGE | 88 ~ 132VAC / 176 ~ 264VAC auto switch 248 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz | |
EFFICIENCY (Typ.) | 80% | |
AC CURRENT (Typ.) | 2.3A/115VAC 1.5A/230VAC | |
INRUSH CURRENT (Typ.) | COLD START 30A/115VAC 60A/230VAC | |
LEAKAGE CURRENT | <1mA / 240VAC | |
PROTECTION | OVER LOAD | 105~ 140% (+24V: above 6.5A) rated output power |
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||
OVER VOLTAGE | 18 ~ 21V | |
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||
ENVIRONMENT | WORKING TEMP. | -10~+60°C (Refer to derating curve) |
WORKING HUMIDITY | 20~90% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -20~+85°C, 10~95%RH | |
TEMP. COEFFICIENT | ±0.05%/°C (0~50°C) | |
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |
SAFETY&EMC (Note 4) | SAFETY STANDARDS | UL60950-1, TUV EN60950-1 approved |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100MOhms/500VDC/25°C/70%RH | |
EMC EMISSION | Compliance to EN55011, EN55022 (CISPR22) Class B, EN61000-3-2,-3 | |
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A | |
OTHERS | MTBF | 203.6Khrs min. MIL-HDBK-217F (25°C) |
DIMENSION | 222*62*32mm (L*W*H) | |
PACKING | 0.45Kg; 24pcs/12.5Kg/1.39CUFT | |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. If the input range 85V-89V, the output load is changed from 0A-rated load, There will be reduced 20V for 1second (LPS-100-24). 6. Mounting holes M1 and M2 should be grounded for EMI purposes. |