Mean well 45W 24V single output power supply/45W power supplies
USD $1 - $10 /Piece
Min.Order:10 Pieces
Hangzhou Nuohan Electronics Co., Ltd.
MODEL | EPS-45-24 | |
OUTPUT | DC VOLTAGE | 24V |
RATED CURRENT | 1.9A | |
CURRENT RANGE | 0 ~ 2.1A | |
RATED POWER | 45.6W | |
PEAK LOAD (10sec.) Note.6 | 50.4W | |
RIPPLE & NOISE (max.) Note.2 | 240mVp-p | |
VOLTAGE ADJ. RANGE | 21.6~ 27V | |
VOLTAGE TOLERANCE Note.3 | ±1.0% | |
LINE REGULATION | ±0.5% | |
LOAD REGULATION | ±1.0% | |
SETUP, RISE TIME | 1000ms, 50ms/230VAC 2000ms, 50ms/115VAC at full load | |
HOLD UP TIME (Typ.) | 50ms/230VAC 16ms/115VAC at full load | |
INPUT | VOLTAGE RANGE Note.5 | 90 ~ 264VAC 127 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz | |
EFFICIENCY (Typ.) | 89% | |
AC CURRENT (Typ.) | 1.8A/115VAC 1A/230VAC | |
INRUSH CURRENT (Typ.) | COLD START 60A/230VAC | |
LEAKAGE CURRENT | <2mA / 240VAC | |
PROTECTION | OVER LOAD | 115 ~ 160% rated output power |
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||
OVER VOLTAGE | 27.6 ~ 32.4V | |
Protection type : Shut down o/p voltage, re-power on to recover | ||
ENVIRONMENT | WORKING TEMP. | -30~+70°C (Refer to derating curve) |
WORKING HUMIDITY | 20~90% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -40~+85°C, 10~95%RH | |
TEMP. COEFFICIENT | ±0.03%/°C(0~50°C) | |
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, Period for 60min.each along X, Y, Z axes | |
SAFETY&EMC (Note 4) | SAFETY STANDARDS | UL60950-1, TUV EN60950-1 Approved |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25°C/70% RH | |
EMCEMISSION | Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 | |
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, heavy industry level, criteria A | |
OTHERS | MTBF | 652.3K hrs min. MIL-HDBK-217F (25°C) |
DIMENSION | PCB: 101.6*50.8*29mm (L*W*H); with optional CASE: 103.4*62*37mm (L*W*H) | |
PACKING | PCB: 0.14Kg; 96pcs/14.5Kg/0.89CUFT; with optional CASE: 0.3Kg; 45pcs/14.5Kg/0.67CUFT | |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Derating may be needed under low input voltage. Please check the static characteristics for more details. 6. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power. |