Meanwell 15W 24v switching power supply PM-15-24 medical approved power supply 15w 24v
USD $1 - $10 /Piece
Min.Order:1 Piece
Hangzhou Nuohan Electronics Co., Ltd.
MODEL | PM-15-24 | |
OUTPUT | DC VOLTAGE | 24V |
RATED CURRENT | 0.63A | |
CURRENT RANGE | 0 ~ 0.63A | |
RATED POWER | 15.12W | |
RIPPLE & NOISE (max.) Note.2 | 240mVp-p | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | |
LINE REGULATION | ±0.5% | |
LOAD REGULATION | ±0.5% | |
SETUP, RISE TIME | 1000ms, 20ms/230VAC 1000ms, 20ms/115VAC at full load | |
HOLD UP TIME (Typ.) | 100ms/230VAC 24ms/115VAC at full load | |
INPUT | VOLTAGE RANGE | 85 ~ 264VAC 120 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 440Hz | |
EFFICIENCY (Typ.) | 81% | |
AC CURRENT (Typ.) | 0.35A/115VAC 0.2A/230VAC | |
INRUSH CURRENT (Typ.) | COLD START 30A/115VAC 50A/230VAC | |
LEAKAGE CURRENT Note.5 | Touch current <80uA/264VAC | |
PROTECTION | OVER LOAD | Above 105% rated output power |
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||
OVER VOLTAGE | 27.6 ~ 32.4V | |
Protection type : Shut off o/p voltage, clamping by zener diode | ||
ENVIRONMENT | WORKING TEMP. | -20~+70°C (Refer to derating curve) |
WORKING HUMIDITY | 20~90% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -40~+85°C, 10~95%RH | |
TEMP. COEFFICIENT | ±0.03%/°C(0~50°C) | |
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |
SAFETY&EMC (Note 4) | SAFETY STANDARDS | ANSI/AAMI ES60601-1, TUV EN60601-1, IEC60601-1 approved |
WITHSTAND VOLTAGE | I/P-O/P:4KVAC | |
ISOLATION RESISTANCE | I/P-O/P:100M Ohms / 500VDC / 25°C/ 70% RH | |
EMC EMISSION | Compliance to EN55011(CISPR11),EN55022 (CISPR22) Class B, EN61000-3-2,-3 | |
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61204-3, medical level, criteria A | |
OTHERS | MTBF | 499.7Khrs min. MIL-HDBK-217F (25°C) |
DIMENSION | 75*53*22.7mm (L*W*H) | |
PACKING | 0.14Kg; 120pcs/17.8Kg/0.97CUFT | |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Touch current was measured from primary input to DC output. 6. Suitable for BF application with appropriate system consideration. |