0.6/1kv 1-Cyky Cable, Ayky Cable IEC 60502 Standard
USD $0.8 - $88 /Meter
Min.Order:500 Meters
Zhengzhou Jinyuan Wire And Cable Co., Ltd.
Na2xs2y Power Cable 10kv 1/C Al/XLPE/Cws/PE HD 620 VDE 0276-620
State Grid N2XSY, N2XS2Y, N2XSEY, NA2XSY and NA2XS2Y. IEC60502-1 and IEC60502-2
High voltage HV 12/20kV COPPER CONDUCTOR XLPE INSULATED CABLE
15KV ALUMINUM CONDUCTOR XLPE INSULATED STEEL WIRE ARMORED CABLE
Middle voltage MV 15KV ALUMINUM CONDUCTOR XLPE INSULATED POWER CABLE
May be you are also interested about
0.6/1kV AL/XLPE/PVC(or PE) Power Cable
0.6/1kV CU/XLPE/PVC(or PE) Power Cable
0.6/1kV CU/XLPE/SWA/PVC(or PE) Power Cable
0.6/1kV CU/XLPE/STA/PVC(or PE) Power Cable
0.6/1kV AL/PVC/ PVC (or PE) Power Cable
0.6/1kV CU/PVC/PVC (or PE) Power Cable
0.6/1kV AL/PVC/SWA/PVC(or PE) Power Cable
0.6/1kV CU/PVC/STA/PVC(or PE) Power Cable
JYTOP CABLE Company Description
1. CE, ISO 9001 Certificaes
2. More than 23 years experiences
3. Professional Manufacturer with Factory located in Henan Province.
4. Quick response and fast delivery.
5. Serve everyone with heart and soul.
0.6/1kv 1-CYKY Cable, AYKY Cable IEC 60502 Standard
DESIGN
1 | Copper conductor, round solid (RE), round stranded (RM), sector-shaped stranded (SM)
2 | Core insulation (PVC)
3 | Inner covering (PVC or plastic tape)
4 | Sheath (PVC, higher flame retardation PVC, UV-restistant PVC)
APPLICATION
Power distribution cables in power stations, industrial installations and switchgears, as well as in local mains. For fi xed installation underground, in interior premises, cable ducts, in the open air, in water - as permitted by the local building regulations - if no risk of any mechanical damage is to be expected.
TECHNICAL DATA for CYKY Cable
Standard: IEC 60502-1
Rated voltage: 0.6/1 kV
Test voltage: 3.5 kV/50 Hz
Temperature range: laying temperature: min. -5 °C operating temperature: -30 °C up to +70 °C conductor temperature: max. +70 °C short-circuit temperature: max. +160 °C/5 s
Bending radius (min.): 15 x O.D of cable (single core) 12 x O.D of cable (multi-core)
Fire properties: flame retardant: EN 60332-1-2
CYKY Cable 450/750v
CYKY Cable 450/750V
0.6/1KV CYKY CABLE
1-CYKY CABLE
Main technical data of 0.6/1KV 1-CYKY Cable, Single core, Copper conductor, PVC insulated and PVC or PE sheath cables
CABLE CONSTRUCTION: 0.6/1KV CU/PVC/PVC or PE
Cable size | Conductor type | Nominal thickness of PVC insulation(mm) | Nominal thickness of PVC sheath(mm) | Approx. cable overall diameter (mm) | Max. D.C resistance @ 200C (Ω/km) |
1x1.5mm2 | RE or RM | 0.8 | 1.4 | 5.8 | 12.1 |
1x2.5mm2 | RE or RM | 0.8 | 1.4 | 6.2 | 7.41 |
1x4mm2 | RE or RM | 1.0 | 1.4 | 7.1 | 4.61 |
1x6mm2 | RE or RM | 1.0 | 1.4 | 7.6 | 3.08 |
1x10mm2 | RM | 1.0 | 1.4 | 8.9 | 1.83 |
1x16mm2 | RM | 1.0 | 1.4 | 9.9 | 1.15 |
1x25mm2 | RM | 1.2 | 1.4 | 11.6 | 0.727 |
1x35mm2 | RM | 1.2 | 1.4 | 12.8 | 0.524 |
1x50mm2 | RM | 1.4 | 1.4 | 14.5 | 0.387 |
1x70mm2 | RM | 1.4 | 1.4 | 16.3 | 0.268 |
1x95mm2 | RM | 1.6 | 1.5 | 18.8 | 0.193 |
1x120mm2 | RM | 1.6 | 1.5 | 20.4 | 0.153 |
1x150mm2 | RM | 1.8 | 1.6 | 22.6 | 0.124 |
1x185mm2 | RM | 2.0 | 1.7 | 25.1 | 0.0991 |
1x240mm2 | RM | 2.2 | 1.8 | 28.3 | 0.0754 |
1x300mm2 | RM | 2.4 | 1.9 | 31.3 | 0.0601 |
1x400mm2 | RM | 2.6 | 2.0 | 34.9 | 0.0470 |
1x500mm2 | RM | 2.8 | 2.1 | 39.1 | 0.0366 |
Note: RE= round conductor RM = stranded conductor SM=sectional conductor
Main technical data of 0.6/1KV 1-CYKY Cable, two cores, Copper conductor, PVC insulated and PVC or PE sheath cables
CABLE CONSTRUCTION: 0.6/1KV CU/PVC/PVC or PE
Cable size | Conductor type | Nominal thickness of PVC insulation(mm) | Nominal thickness of PVC sheath(mm) | Approx. cable overall diameter (mm) | Max. D.C resistance @ 200C (Ω/km) |
2x1.5mm2 | RE or RM | 0.8 | 1.8 | 9.7 | 12.1 |
2x2.5mm2 | RE or RM | 0.8 | 1.8 | 10.5 | 7.41 |
2x4mm2 | RE or RM | 1.0 | 1.8 | 12.3 | 4.61 |
2x6mm2 | RE or RM | 1.0 | 1.8 | 13.3 | 3.08 |
2x10mm2 | RM | 1.0 | 1.8 | 15.9 | 1.83 |
2x16mm2 | RM | 1.0 | 1.8 | 18.0 | 1.15 |
2x25mm2 | SM | 1.2 | 1.8 | 16.7 | 0.727 |
2x35mm2 | SM | 1.2 | 1.8 | 18.2 | 0.524 |
2x50mm2 | SM | 1.4 | 1.8 | 20.5 | 0.387 |
2x70mm2 | SM | 1.4 | 1.9 | 23.1 | 0.268 |
2x95mm2 | SM | 1.6 | 2.0 | 26.5 | 0.193 |
2x120mm2 | SM | 1.6 | 2.1 | 28.8 | 0.153 |
2x150mm2 | SM | 1.8 | 2.3 | 31.9 | 0.124 |
2x185mm2 | SM | 2.0 | 2.4 | 35.3 | 0.0991 |
2x240mm2 | SM | 2.2 | 2.5 | 39.6 | 0.0754 |
2x300mm2 | SM | 2.4 | 2.7 | 43.8 | 0.0601 |
Note: RE= round conductor RM = stranded conductor SM=sectional conductor
Main technical data of 0.6/1KV 1-CYKY Cable, three cores, Copper conductor, PVC insulated and PVC or PE sheath cables
CABLE CONSTRUCTION: 0.6/1KV CU/PVC/PVC or PE
Cable size | Conductor type | Nominal thickness of PVC insulation(mm) | Nominal thickness of PVC sheath(mm) | Approx. cable overall diameter (mm) | Max. D.C resistance @ 200C (Ω/km) |
3x1.5mm2 | RE or RM | 0.8 | 1.8 | 10.2 | 12.1 |
3x2.5mm2 | RE or RM | 0.8 | 1.8 | 11.1 | 7.41 |
3x4mm2 | RE or RM | 1.0 | 1.8 | 12.9 | 4.61 |
3x6mm2 | RE or RM | 1.0 | 1.8 | 14.0 | 3.08 |
3x10mm2 | RM | 1.0 | 1.8 | 16.8 | 1.83 |
3x16mm2 | RM | 1.0 | 1.8 | 19.1 | 1.15 |
3x25mm2 | SM | 1.2 | 1.8 | 19.4 | 0.727 |
3x35mm2 | SM | 1.2 | 1.8 | 21.3 | 0.524 |
3x50mm2 | SM | 1.4 | 1.8 | 24.1 | 0.387 |
3x70mm2 | SM | 1.4 | 2.0 | 27.5 | 0.268 |
3x95mm2 | SM | 1.6 | 2.1 | 31.6 | 0.193 |
3x120mm2 | SM | 1.6 | 2.2 | 34.3 | 0.153 |
3x150mm2 | SM | 1.8 | 2.3 | 37.8 | 0.124 |
3x185mm2 | SM | 2.0 | 2.5 | 42.2 | 0.0991 |
3x240mm2 | SM | 2.2 | 2.7 | 47.5 | 0.0754 |
3x300mm2 | SM | 2.4 | 2.9 | 52.3 | 0.0601 |
Note: RE= round conductor RM = stranded conductor SM=sectional conductor
Main technical data of 0.6/1KV,1-CYKY Cable 3+1 cores, Copper conductor, PVC insulated and PVC or PE sheath cables
CABLE CONSTRUCTION: 0.6/1KV CU/PVC/PVC or PE
Cable size | Conductor type | Nominal thickness of PVC insulation(mm) | Nominal thickness of PVC sheath(mm) | Approx. cable overall diameter (mm) | Max. D.C resistance @ 200C (Ω/km) | |||
Phase core | Earth core | Phase core | Earth core | Phase core | Earth core | |||
3x2.5+1.5mm2 | RE | RE | 0.8 | 0.8 | 1.8 | 11.7 | 7.41 | 12.1 |
3x4+2.5mm2 | RE | RE | 1.0 | 0.8 | 1.8 | 13.5 | 4.61 | 7.41 |
3x6+4mm2 | RE | RE | 1.0 | 1.0 | 1.8 | 15.0 | 3.08 | 4.61 |
3x10+6mm2 | RM | RE | 1.0 | 1.0 | 1.8 | 17.6 | 1.83 | 3.08 |
3x16+10mm2 | RM | RM | 1.0 | 1.0 | 1.8 | 20.3 | 1.15 | 1.83 |
3x25+16mm2 | SM | RM | 1.2 | 1.0 | 1.8 | 21.4 | 0.727 | 1.15 |
3x35+16mm2 | SM | RM | 1.2 | 1.0 | 1.8 | 23.1 | 0.524 | 1.15 |
3x50+25mm2 | SM | SM | 1.4 | 1.2 | 1.9 | 26.3 | 0.387 | 0.727 |
3x70+35mm2 | SM | SM | 1.4 | 1.2 | 2.0 | 30.0 | 0.268 | 0.524 |
3x95+50mm2 | SM | SM | 1.6 | 1.4 | 2.2 | 34.3 | 0.193 | 0.387 |
3x120+70mm2 | SM | SM | 1.6 | 1.4 | 2.3 | 37.6 | 0.153 | 0.268 |
3x150+70mm2 | SM | SM | 1.8 | 1.4 | 2.4 | 40.8 | 0.124 | 0.268 |
3x185+95mm2 | SM | SM | 2.0 | 1.6 | 2.6 | 45.7 | 0.0991 | 0.193 |
3x240+120mm2 | SM | SM | 2.2 | 1.6 | 2.8 | 51.3 | 0.0754 | 0.153 |
3x300+150mm2 | SM | SM | 2.4 | 1.8 | 2.9 | 56.6 | 0.0601 | 0.124 |
Note: RE= round conductor RM = stranded conductor SM=sectional conductor
Main technical data of 0.6/1KV,1-CYKY Cable four cores, Copper conductor, PVC insulated and PVC or PE sheath cables
CABLE CONSTRUCTION: 0.6/1KV CU/PVC/PVC or PE
Cable size | Conductor type | Nominal thickness of PVC insulation(mm) | Nominal thickness of PVC sheath(mm) | Approx. cable overall diameter (mm) | Max. D.C resistance @ 200C (Ω/km) |
4x1.5mm2 | RE or RM | 0.8 | 1.8 | 11.0 | 12.1 |
4x2.5mm2 | RE or RM | 0.8 | 1.8 | 11.9 | 7.41 |
4x4mm2 | RE or RM | 1.0 | 1.8 | 14.0 | 4.61 |
4x6mm2 | RE or RM | 1.0 | 1.8 | 15.3 | 3.08 |
4x10mm2 | RM | 1.0 | 1.8 | 18.4 | 1.83 |
4x16mm2 | RM | 1.0 | 1.8 | 20.9 | 1.15 |
4x25mm2 | SM | 1.2 | 1.8 | 21.9 | 0.727 |
4x35mm2 | SM | 1.2 | 1.8 | 24.1 | 0.524 |
4x50mm2 | SM | 1.4 | 1.9 | 27.6 | 0.387 |
4x70mm2 | SM | 1.4 | 2.1 | 31.4 | 0.268 |
4x95mm2 | SM | 1.6 | 2.2 | 36.1 | 0.193 |
4x120mm2 | SM | 1.6 | 2.3 | 39.3 | 0.153 |
4x150mm2 | SM | 1.8 | 2.5 | 43.5 | 0.124 |
4x185mm2 | SM | 2.0 | 2.7 | 48.4 | 0.0991 |
4x240mm2 | SM | 2.2 | 2.9 | 54.6 | 0.0754 |
4x300mm2 | SM | 2.4 | 3.1 | 60.4 | 0.0601 |
Note: RE= round conductor RM = stranded conductor SM=sectional conductor
NOTE:
If you want to know more details about 1-CYKY Cable this kind of products, please visit our website(homepage) because we have no ways to show so much information on this platform. Thank you.
We can producing the pvc cable and xlpe cable, according to different Standards, such as BS,DIN,ASTM,IEC and so on, for the Armoured cable, there are Steel wire armoured, steel tape armoured and Aluminum wire armoured type available. YKY Cable usually is suitable for Europe market with CE certificate.
Certificates
Customers Visit
Some Project
1. Is it a cable factory?
Definitely, we are a wire and cable Manufacturer with 23 years history, our factory located in Zhengzhou, Henan Province,China.
2. Any certificates:
Yes, the CE and ISO 9001:2008 are available.
For bare conductors there are Type Test Report available
3. What Standards you are using?
We can producing the wire and cables according to the popular Standards, such as IEC, ASTM, BS, DIN,SANS,CSA or as the clients requirements
4. OEM services?
Yes, We supply OEM services.
5. Delivery time
It depends on the cable type and quantity you need, you can contact us for the details
6. Payment terms:
Usually we would prefer L/C, T/T, or negotiate with us.
7. Packing
Usually it is packing in coil for PVC builing wire, for the powe cable and bare conductors used to packing by Drums, or as clients requirements.
HOT SALE CABLE
CONTACT