15kv copper conductor xlpe insulated copper wire shield power cable
USD $1.8 - $66 /Meter
Min.Order:500 Meters
Zhengzhou Jinyuan Wire And Cable Co., Ltd.
HV STEEL WIRE ARMORED CABLE 26/35kV ALUMINUM CONDUCTOR XLPE INSULATED STEEL WIRE ARMORED CABLE
HV ALUMINUM WIRE ARMORED CABLE 21/35kV ALUMINUM CONDUCTOR XLPE INSULATED ALUMINUM WIRE ARMORED CABLE
high voltage 18/30kv aluminum conductor xlpe insulated aluminum wire armored power cable
high voltage aluminum conductor xlpe insulated aluminum wire armoredcable
middle voltage 15kv aluminum conductor xlpe insulated aluminum wire armored cable
Middle voltage MV 11KV ALUMINUM CONDUCTOR XLPE INSULATED ALUMINUM WIRE ARMORED CABLE
15KV COPPER CONDUCTOR XLPE INSULATED COPPER WIRE SHIELD CABLE
1. Description
Construction: Compacted stranded circular copper conductor, extruded semi-conducting compound as conductor shield, cross-linked polyethylene (XLPE) insulation, semi-conducting compound as insulation shield, copper tape or combination of copper wire and tape as metallic screen, three cores assembled together with non-hygroscopic polypropylene filler, wrapped with binder tape, PVC or PE outer sheath.
Chinese Type | Description | Core qty | Conductors range |
YJV | Copper conductor, XLPE insulation, PVC outer sheath Power Cable | 1 or 3 | 25~800mm2 |
YJY | Copper conductor, XLPE insulation, PE outer sheath Power Cable | 1 or 3 | 25~800mm2 |
ZA-YJV ZB-YJV ZC-YJV | Copper conductor, XLPE insulation flame-retardant Power Cable | 1 or 3 | 25~800mm2 |
WDZA-YJY WDZB-YJY WDZC-YJY | Copper conductor, XLPE insulation Low Smoke Halogen Free or Zero Halogen (LSHF or LSZH) flame-retardant Power Cable | 1 or 3 | 25~800mm2 |
2. Operating Characteristics
Rated voltage U0/U(Um): 8.7/15(17.5)kV
U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;
U is the rated power frequency voltage between conductors for which the cable is designed;
Um is the maximum value of the “highest system voltage” for which the equipment may be used.
Max. permissible continuous operating temperature of conductor: 90 °C
Max. temperature of conductor during short-circuit (5s max. duration) shall not exceed: 250 °C
The ambient temperature under installation should not be lower than: 0 °C
The bending radius of cable is recommended as following:
For single core cable: not less than 20 times of the diameter of cable
For three core cable: not less than 15 times of the diameter of cable
3. Application
The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid indoors, outdoors, in tunnel or in cable trench, unable to bear external mechanical force.
Single core cable in magnetic duct is not permissible.
Main technical data of 8.7/15KV Single core, Copper conductor, XLPE insulated, copper wire screened and PVC or PE sheath cable
Size | Nominal thickness of XLPE insulation(mm) | Approx. thickness of copper tape screen (mm) | Nominal diameter of copper wire(mm) | Nominal thickness of PVC or PE(mm) | Approx. overall diameter of finished cable(mm) | Max. conductor D.C resistance @ 200C (Ω/km) |
1x25mm2 | 4.5 | 0.12 | 0.9 | 1.8 | 24.2 | 0.727 |
1x35mm2 | 4.5 | 0.12 | 0.9 | 1.8 | 25.2 | 0.524 |
1x50mm2 | 4.5 | 0.12 | 0.9 | 1.8 | 26.3 | 0.387 |
1x70mm2 | 4.5 | 0.12 | 0.9 | 1.8 | 28.0 | 0.268 |
1x95mm2 | 4.5 | 0.12 | 0.9 | 1.8 | 29.6 | 0.193 |
1x120mm2 | 4.5 | 0.12 | 0.9 | 1.9 | 31.2 | 0.153 |
1x150mm2 | 4.5 | 0.12 | 0.9 | 1.9 | 32.8 | 0.124 |
1x185mm2 | 4.5 | 0.12 | 0.9 | 2.0 | 34.6 | 0.0991 |
1x240mm2 | 4.5 | 0.12 | 0.9 | 2.1 | 37.2 | 0.0754 |
1x300mm2 | 4.5 | 0.12 | 0.9 | 2.1 | 39.2 | 0.0601 |
1x400mm2 | 4.5 | 0.12 | 0.9 | 2.3 | 42.8 | 0.0470 |
1x500mm2 | 4.5 | 0.12 | 0.9 | 2.3 | 46.3 | 0.0366 |
1x630mm2 | 4.5 | 0.12 | 0.9 | 2.5 | 50.5 | 0.0283 |
1x800mm2 | 4.5 | 0.12 | 0.9 | 2.6 | 54.5 | 0.0221 |
MV & HV XLPE POWER CABLE PRODUCTION LINE
VARIOUS EXPORT PACKING AS PER CUSTOMER'S DEMANDS