Middle voltage MV 15KV ALUMINUM CONDUCTOR XLPE INSULATED POWER CABLE
USD $1.2 - $44 /Meter
Min.Order:500 Meters
Zhengzhou Jinyuan Wire And Cable Co., Ltd.
Middle voltage MV 15KV ALUMINUM CONDUCTOR XLPE INSULATED POWER CABLE
8.7/15kV AL/XLPE/PVC(or PE) Power Cable
1. Description 15KV ALUMINUM XLPE INSULATED CABLE 15KV ALUMINUM XLPE Construction: Compacted stranded circular aluminum conductor, extruded semi-conducting compound as conductor shield, cross-linked polyethylene (XLPE) insulation, semi-conducting compound as insulation shield, copper tape or combination of copper wire and tape as metallic screen, three cores assembled together with non-hygroscopic polypropylene filler, wrapped with binder tape, PVC or PE outer sheath.
Chinese Type | Description | Core qty | Conductors range |
YJLV | Aluminum conductor, XLPE insulation, PVC outer sheath Power Cable | 1 or 3 | 25~800mm2 |
YJLY | Aluminum conductor, XLPE insulation, PE outer sheath Power Cable | 1 or 3 | 25~800mm2 |
ZA-YJLV ZB-YJLV ZC-YJLV | Aluminum conductor, XLPE insulation flame-retardant Power Cable | 1 or 3 | 25~800mm2 |
WDZA-YJLY WDZB-YJLY WDZC-YJLY | Aluminum conductor, XLPE insulation Low Smoke Halogen Free or Zero Halogen (LSHF or LSZH) flame-retardant Power Cable | 1 or 3 | 25~800mm2 |
2. Operating Characteristics
Rated voltage U0/U(Um): 8.7/15(17.5)kV
U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;
U is the rated power frequency voltage between conductors for which the cable is designed;
Um is the maximum value of the “highest system voltage” for which the equipment may be used.
Max. permissible continuous operating temperature of conductor: 90 °C
Max. temperature of conductor during short-circuit (5s max. duration) shall not exceed: 250 °C
The ambient temperature under installation should not be lower than: 0 °C
The bending radius of cable is recommended as following:
For single core cable: not less than 20 times of the diameter of cable
For three core cable: not less than 15 times of the diameter of cable
3. Application
The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid indoors, outdoors, in tunnel or in cable trench, unable to bear external mechanical force.
Single core cable in magnetic duct is not permissible.
Technical data of 8.7/15KV, three cores, Aluminum conductor, XLPE insulated, and PVC or PE sheath cable
Size | Nominal thickness of XLPE insulation(mm) | Approx. thickness of copper tape screen (mm) | Nominal thickness of PVC or PE(mm) | Approx. overall diameter of finished cable(mm) | Max. conductor D.C resistance @ 200C (Ω/km) |
3x25mm2 | 4.5 | 0.10 | 2.4 | 46.3 | 1.20 |
3x35mm2 | 4.5 | 0.10 | 2.5 | 48.7 | 0.868 |
3x50mm2 | 4.5 | 010 | 2.6 | 51.3 | 0.641 |
3x70mm2 | 4.5 | 0.10 | 2.7 | 55.3 | 0.443 |
3x95mm2 | 4.5 | 0.10 | 2.8 | 59.0 | 0.320 |
3x120mm2 | 4.5 | 0.10 | 2.9 | 62.3 | 0.253 |
3x150mm2 | 4.5 | 0.10 | 3.0 | 66.0 | 0.206 |
3x185mm2 | 4.5 | 0.10 | 3.1 | 69.7 | 0.164 |
3x240mm2 | 4.5 | 0.10 | 3.3 | 75.4 | 0.125 |
3x300mm2 | 4.5 | 0.10 | 3.4 | 80.0 | 0.100 |
3x400mm2 | 4.5 | 0.10 | 3.7 | 87.6 | 0.0778 |