15kv copper conductor xlpe insulated power cable
USD $1.8 - $66 /Meter
Min.Order:500 Meters
Zhengzhou Jinyuan Wire And Cable Co., Ltd.
15KV COPPER CONDUCTOR XLPE INSULATED POWER CABLE
8.7/15kV CU/XLPE/PVC(or PE) Power Cable
COPPER CABLE 15KV COPPER CABLE 15KV COPPER CABLE
1. Construction: Compacted stranded circular copper conductor, extruded semi-conducting compound as conductor shield, cross-linked polyethylene (XLPE) insulation, semi-conducting compound as insulation shield, copper tape or combination of copper wire and tape as metallic screen, three cores assembled together with non-hygroscopic polypropylene filler, wrapped with binder tape, PVC or PE outer sheath.
Chinese Type | Description | Core qty | Conductors range |
YJV | Copper conductor, XLPE insulation, PVC outer sheath Power Cable | 1 or 3 | 25~800mm2 |
YJY | Copper conductor, XLPE insulation, PE outer sheath Power Cable | 1 or 3 | 25~800mm2 |
ZA-YJV ZB-YJV ZC-YJV | Copper conductor, XLPE insulation flame-retardant Power Cable | 1 or 3 | 25~800mm2 |
WDZA-YJY WDZB-YJY WDZC-YJY | Copper conductor, XLPE insulation Low Smoke Halogen Free or Zero Halogen (LSHF or LSZH) flame-retardant Power Cable | 1 or 3 | 25~800mm2 |
2. Operating Characteristics
Rated voltage U0/U(Um): 8.7/15(17.5)kV
U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;
U is the rated power frequency voltage between conductors for which the cable is designed;
Um is the maximum value of the “highest system voltage” for which the equipment may be used.
Max. permissible continuous operating temperature of conductor: 90 °C
Max. temperature of conductor during short-circuit (5s max. duration) shall not exceed: 250 °C
The ambient temperature under installation should not be lower than: 0 °C
The bending radius of cable is recommended as following:
For single core cable: not less than 20 times of the diameter of cable
For three core cable: not less than 15 times of the diameter of cable
3. Application
The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid indoors, outdoors, in tunnel or in cable trench, unable to bear external mechanical force.
Single core cable in magnetic duct is not permissible.
Main technical data of 8.7/15KV, three cores, Copper conductor, XLPE insulated, and PVC or PE sheath cable CABLE CONSTRUCTION: 8.7/15KV CU/XLPE/PVC or PE
Size | Nominal thickness of XLPE insulation(mm) | Approx. thickness of copper tape screen (mm) | Nominal thickness of PVC or PE(mm) | Approx. overall diameter of finished cable(mm) | Max. conductor D.C resistance @ 200C (Ω/km) |
3x25mm2 | 4.5 | 0.10 | 2.4 | 46.3 | 0.727 |
3x35mm2 | 4.5 | 0.10 | 2.5 | 48.7 | 0.524 |
3x50mm2 | 4.5 | 010 | 2.6 | 51.3 | 0.387 |
3x70mm2 | 4.5 | 0.10 | 2.7 | 55.3 | 0.268 |
3x95mm2 | 4.5 | 0.10 | 2.8 | 59.0 | 0.193 |
3x120mm2 | 4.5 | 0.10 | 2.9 | 62.3 | 0.153 |
3x150mm2 | 4.5 | 0.10 | 3.0 | 66.0 | 0.124 |
3x185mm2 | 4.5 | 0.10 | 3.1 | 69.7 | 0.0991 |
3x240mm2 | 4.5 | 0.10 | 3.3 | 75.4 | 0.0754 |
3x300mm2 | 4.5 | 0.10 | 3.4 | 80.0 | 0.0601 |
3x400mm2 | 4.5 | 0.10 | 3.7 | 87.6 | 0.0470 |
23 years cable manufacturing experience, certifications are as follows:
15KV COPPER CABLE 15KV COPPER CABLE 15KV COPPER CABLE 15KV COPPER CABLE 15KV COPPER CABLE