high voltage 18/30kv aluminum conductor xlpe insulated aluminum wire armored power cable
USD $5.8 - $98 /Meter
Min.Order:500 Meters
Zhengzhou Jinyuan Wire And Cable Co., Ltd.
high voltage aluminum conductor xlpe insulated aluminum wire armoredcable
middle voltage 15kv aluminum conductor xlpe insulated aluminum wire armored cable
Middle voltage MV 11KV ALUMINUM CONDUCTOR XLPE INSULATED ALUMINUM WIRE ARMORED CABLE
High Voltage HV 26/35kV COPPER CONDUCTOR XLPE INSULATED STEEL TAPE ARMORED CABLE 3 CORE
High Voltage HV 21/35kV Copper CONDUCTOR XLPE INSULATED STEEL TAPE ARMORED CABLE
MIDDLE VOLTAGE MV 11kv copper conductor XLPE insulated steel wire armored power cable
High Voltage HV 18/30kV Aluminum CONDUCTOR XLPE INSULATED ALUMINUM WIRE ARMORED CABLE
1. Description
Construction: Compacted stranded circular aluminum conductor, extruded semi-conducting compound as conductor shield, cross-linked polyethylene (XLPE) insulation, semi-conducting compound as insulation shield, copper tape or combination of copper wire and tape as metallic screen, three cores assembled together with non-hygroscopic polypropylene filler, wrapped with binder tape, PVC inner covering as armoring bedding, galvanized steel wire armored, PVC or PE outer sheath.
Chinese Type | Description | Core qty | Conductors range |
YJLV32 | Aluminum conductor, XLPE insulation, Steel Wire Armored, PVC outer sheath Power Cable | 1 or 3 | 50~800mm2 |
YJLV33 | Aluminum conductor, XLPE insulation, Steel Wire Armored, PE outer sheath Power Cable | 1 or 3 | 50~800mm2 |
ZA-YJLV32 ZB-YJLV32 ZC-YJLV32 | Aluminum conductor, XLPE insulation, Steel Wire Armored flame-retardant Power Cable | 1 or 3 | 50~800mm2 |
WDZA-YJLY33 WDZB-YJLY33 WDZC-YJLY33 | Aluminum conductor, XLPE insulation, Steel Wire Armored Low Smoke Halogen Free or Zero Halogen (LSHF or LSZH) flame-retardant Power Cable | 1 or 3 | 50~800mm2 |
2.Operating Characteristics
Rated voltage U0/U(Um): 18/30(36)kV
U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;
U is the rated power frequency voltage between conductors for which the cable is designed;
Um is the maximum value of the “highest system voltage” for which the equipment may be used.
Max. permissible continuous operating temperature of conductor: 90 °C
Max. temperature of conductor during short-circuit (5s max. duration) shall not exceed: 250 °C
The ambient temperature under installation should not be lower than: 0 °C
The bending radius of cable is recommended as following:
For single core cable: not less than 15 times of the diameter of cable
For three core cable: not less than 12 times of the diameter of cable
When the armored single core cable used for Alternative Current(AC) system, the armoring material should be non-magnetic.
Main technical data of 18/30KV Single core, Aluminum conductor, XLPE insulated, copper wire screened, pure aluminum wire armored and PVC or PE sheath cable
Size | Nominal thickness of XLPE insulation(mm) | Approx. thickness of copper tape screen (mm) | Nominal diameter of copper wire(mm) | Approx. diameter of aluminum wire (mm) | Nominal thickness of PVC or PE(mm) | Approx. overall diameter of finished cable(mm) | Max. conductor D.C resistance @ 200C (Ω/km) |
1x50mm2 | 8.0 | 0.12 | 0.9 | 2.0 | 2.2 | 40.8 | 0.641 |
1x70mm2 | 8.0 | 0.12 | 0.9 | 2.0 | 2.3 | 42.7 | 0.443 |
1x95mm2 | 8.0 | 0.12 | 0.9 | 2.0 | 2.3 | 44.3 | 0.320 |
1x120mm2 | 8.0 | 0.12 | 0.9 | 2.5 | 2.4 | 47.1 | 0.253 |
1x150mm2 | 8.0 | 0.12 | 0.9 | 2.5 | 2.5 | 48.9 | 0.206 |
1x185mm2 | 8.0 | 0.12 | 0.9 | 2.5 | 2.5 | 50.5 | 0.164 |
1x240mm2 | 8.0 | 0.12 | 0.9 | 2.5 | 2.6 | 53.3 | 0.125 |
1x300mm2 | 8.0 | 0.12 | 0.9 | 2.5 | 2.7 | 55.5 | 0.100 |
1x400mm2 | 8.0 | 0.12 | 0.9 | 2.5 | 2.8 | 59.1 | 0.0778 |
1x500mm2 | 8.0 | 0.12 | 0.9 | 2.5 | 2.9 | 62.9 | 0.0605 |
1x630mm2 | 8.0 | 0.12 | 0.9 | 2.5 | 3.0 | 67.0 | 0.0469 |
1x800mm2 | 8.0 | 0.12 | 0.9 | 2.5 | 3.1 | 70.9 | 0.0369 |