Data conversion between DCS and process skid mounted equipment
In a specific use case, a biopharmaceutical company from India hopes to use such a DCS to control various independent process mounted equipment from different manufacturers. However, the process sled uses PROFINET IO as the communication protocol, while the DCS of the pharmaceutical factory relies on EtherNet/IP, which proposes how to combine the tasks of these two types of devices.
Reduce costs and complexity
Normally, the biopharmaceutical company must integrate the process sled through an independent IO card from the DCS, which results in high engineering costs and a risk of long debugging time. In this regard, netTAP 151 plays a role as it provides a simple, fast, and flexible solution for converting various real-time Ethernet protocols. It can provide universal conversion from various common industrial communication protocols to EtherNet/IP, and DCS can easily integrate different process sleds, promoting the integration of complex pharmaceutical and chemical production processes.
Flexible protocol conversion using netTAP
NetTAP 151 facilitates the integration of third-party process mounted equipment in the manufacturing process. Although in this case, the conversion of industrial communication protocols only requires PROFINET IO to EtherNet/IP, the customer's range of options is not limited to this.
Benefiting from the multi-protocol characteristics of Heyouxun, automatic resolution
Contact information: 15359293870
WhatsApp:+86 15359293870
Contact person: KELLY
Email: geabbdcs@gmail.com 386353502@qq.com
Official website:
● Input signal:
Thermocouples: K, S, R, WRe3-25, WRe5-26, E, J, T, B, N, etc
Thermal resistance: Pt100, Cu50, Cu53, etc
Linear voltage: 0-1V, 0-100V, 0-2mV, etc
Linear current: 4-20mA, 0-20mA, etc
Linear resistance: 0-80 Ω, 0-400 Ω
Note: When inputting resistance, it must be a three wire wiring method, and the lead resistance on the three wires must be consistent and less than 18 Ω.
Measurement accuracy: ± 0.2% (0.2% F.S)
Communication output: Rs485 communication interface, Modbus-RTU communication protocol
Isolation voltage: input power supply, output power supply: 1000VAC/1 minute
Working environment: temperature, 0-50 ℃; Relative humidity ≤ 80% RH
Power supply: Switching power supply 100-240VAC (50HZ/60HZ), switching power supply 24VDC/AC ± 2V
Power consumption: ≤ 4W
Appearance color: white
Installation size: 100 × one hundred and twelve × 23mm installation method: DIN35 guide rail