MPL-B540K-SJ24AA/A
MPL-B540K-SJ24AA/A
MPL-B540K-SJ24AA/A

MPL-B540K-SJ24AA/A

USD $1016 - $2027 /Piece

Min.Order:1 Piece

Supply Ability:
69 Piece / Pieces per Month
Payment Terms:
T/T

Quick Details View All >

Brand Name:
MPL-B540K-SJ24AA/A
Place of Origin:
China
Model Number:
MPL-B540K-SJ24AA/A

Temporal Ming sheng automation equipment co., LTD

Business license
Main Products: ABB、GE、MOTOROLA、BENTLY、EMERSON、HIMA、TRICONEX

Product Details

Brand: A - B

Type:MPL-B540K-SJ24AA/A

Origin: the United States

Warranty: 365 days

Colour: new/used

Shipping method: Courier delivery

Overcurrent Protection The 5.1 VDC output is electronically limited to 7 Amps. The 3.3 VDC output is limited to 10 Amps. If an overload (including short circuits) occurs, it is sensed internally and the Power Supply shuts down. The Power Supply continually tries to restart until the overload condition is removed. An internal fuseable link in the input line is provided as a backup. The Power Supply usually shuts down before the fuse blows. The fuse also protects against internal supply faults. The CPU Fault Table shows a fault if any Overtemperature, Overload, or P/S Fault occurs. There is no additional indication if the Power Supply fuse blows. Field Wiring: IC695PSA040 Power Source and Ground Connections The wires from the power source and ground connect to the terminals on the Power Supply as shown at right. Warning If the same external DC power source is used to provide power to two or more power supplies in the system, connection polarity must be identical at each RX3i power supply. A resulting difference in potential can injure personnel or cause damage to equipment. Also, each backplane must be connected to a common system ground. 

Keep as short as possible. Connect directly to mounting panel. + L1 + L1 - N/ L2 - N/ L2 To additional units To additional units Input Overvoltage Protection The bottom terminal is normally connected to frame ground with a user-installed jumper as shown at lower right. If overvoltage protection is not required or is supplied upstream, no jumper is required. To Hi-pot test this supply, overvoltage protection must be disabled during the test by removing the jumper. Re-enable overvoltage protection after testing by reinstalling the jumper.Each terminal accepts one AWG 14 to AWG 22 wire. The end of each wire should be stripped at least 3/8-inch (9mm). The terminal can accept a wire that is stripped up to 11 mm (.433 in) while providing full seating of the insulator. The wire must be fully inserted as shown at left, so that the insulation meets the insulation stop position inside the terminal. Tightening the terminal screw pivots the clamp firmly against the stripped end of the wire, holding it in place. If the wire is not fully inserted as shown at right, tightening the terminal screw may push the wire upward so that it is not connected.

Contact Supplier

Ms. Chat Now

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Other Electrical Equipment
Categories
Hi~