FEM100 P0973CA
USD $1102 - $2012 /Piece
Min.Order:1 Piece
Temporal Ming sheng automation equipment co., LTD
Brand:FOXBORO
Type:FEM100 P0973CA
Origin: the United States
Warranty: 365 days
Colour: new/used
Shipping method: Courier delivery
• Cost- and space-optimized compact module, especially well suited for plastic machines • Supports the “fast control” concept • Functions for changeover point recognition • Connection via high-performance EtherCAT connection • Direct expandability by means of KeConnect C2 modules • Extensive diagnostic options
The IM 270/W is a cost- and space-saving compact module. It combines the typical I/O design for plastic injection molding machines in one module and offers functions for changeover point detection. In addition to application in the plastics sector, it can also be used in other areas. The IM 270/W supports the “fast control” concept. Innovative EtherCAT communication between the compact module and the CPU module is used here to minimize dead times and thereby greatly reduce reaction times. This increases the performance of the machine considerably. Depending on the type of inputs and outputs, various diagnostic possibilities are available, such as the detection of sensor failures or short circuits. The IM 270/W is connected to the CPU module via EtherCAT. To adapt the I/O configuration to the application, KeConnect C2 modules can be attached at the side directly via the K-bus.
• Thermoelement type J, K, L (TM 220/A, TM 240/A) • For PT100 sensors (TM 225/A) • Internal and external cold junction compensation • High measurement precision • Sensor failure detection • Electronic parameter chip
Short description The TM 2xx/A series consists of temperature measurement modules that can be directly attached to CPU modules and operated with all product lines of the KEBA control system by means of bus couplers. TM 220/A, TM 240/A Analog input modules TM 220/A and TM 240/A enable the direct connection of thermoelements (2-conductor technique).
The calibration and linearization of the temperature values takes place via a microcontroller. A sensor failure, should it occur, is reported to the higher-level central module and can be evaluated in the application. Two operating modes are supported: • Display of the actually measured temperature (standard mode) • Display of the measured voltage in μV Cold junction compensation can occur via internal temperature measurement at the terminals of the module or optionally with the aid of external sensor TE 220/A (external terminal temperature compensation). TM 225/A Analog input module TM 225/A enables the direct connection of PT100 resistor sensors. Up to four temperature sensors can be operated with 2- or 4-conductor technique. With the 4-conductor technique, the interference associated with the conductor lengths is compensated for and the precision of the measurement thereby increased