Customized Sterilization Cycles Medical Waste Autoclave Treatment Equipment
Negotiable /Set
Min.Order:1 Set
Professional Horizontal 316L Chamber Double Door Autoclave With Sliding Door
Double Door Hospital Steam Sterilizers With Full Jacket SS304 Chamber
Non - proprietary Parts Veterinary Autoclave With Independent Recording
Saturated Steam Double Door Autoclave With Safety Chamber Door System
Multiple Sterilization Cycles 120 Liter Double Door Laboratory Autoclave
1500 Liter Large Capacity Horizontal Autoclave With Stainless Steel Trolley
Quick Details:
2 motorized hinge doors Rectangular chamber, completely made of stainless steel AISI 316L or AISI 304 and entirely covered with a full steam jacket High effective vacuum pump 3 integrated sterilization programs and free program, allowing to select time and temperature, drying and cooling 2 test programs (Leak test and Bowie-Dick test for control of steam penetration into porous materials) A wide range of parameter adjustment is available for each program 5.7\" colour touch screen display indicating in real time: HEPA exhaust air filter Filter for outgoing condensate from the chamberApplications:
The Medical Waste Autoclave Line is designed to service hospitals and large medical
centers that need to process high volumes of medical waste safely and on site
Model Chart:
Model |
Chamber Size |
Overall Size |
Net Weight |
Steam |
Water |
Power |
W*H*D mm |
W*H*D mm |
Kg |
Kg/cycle |
Kg/cycle |
KVA |
|
MD-0.24 |
600*600*670 |
1500*1800*1010 |
700 |
20 |
230 |
2 |
MD-0.36 |
600*600*1000 |
1500*1800*1340 |
800 |
25 |
240 |
2 |
MD-0.6 |
610*910*1170 |
1500*1900*1510 |
1250 |
30 |
260 |
3 |
MD-0.8 |
610*910*1450 |
1500*1900*1790 |
1400 |
35 |
280 |
3 |
MD-1.0 |
680*1180*1250 |
1600*2000*1590 |
1550 |
40 |
300 |
4 |
MD-1.2 |
680*1180*1500 |
1600*2000*1840 |
1950 |
45 |
320 |
4 |
Materials :
1. Chamber/Jacket: three types are optional, SS304/Steel, SS304/SS304 or SS316L/SS304
2. Door: interior surface material same as the chamber’s
3. Loading trays or loading carts: SS304/SS316L, same as the chamber’s
4. Trolleys: SS304
5. Stand & frame: painted Mild Steel or stainless steel
6. External cover: brushed stainless steel
Safety Features:
A cycle cannot start until the doors are locked and sealed. Steam / heating cannot be applied to the chamber unless the doors are locked and sealed. The door release is interlocked with the chamber safety pressure limit to ensure all residual pressure has completely and effectively vented to atmosphere before the doors can be opened. The doors will retain their positions in the event of failure of any service. The doors are thermally insulated to prevent the surface temperature presenting a hazard to operators. If the pressure in the chamber exceeds 10KPa the doors remains locked.Sterilization Cycles:
Cycle No. |
Cycle Name |
Further Details |
1 |
Solid waste |
3 times Vacuum, expose temperature 132℃, expose time 8 min, drying time 5 min. |
2 |
Liquid waste |
15 min exchange, expose temperature 121℃, expose time 15 min, cooling time 25 min. |
3 |
B-D Test |
3 times Vacuum, expose temperature 134℃, expose time 4 min, drying time 3 min. |
4 |
Vacuum Leakage Test |
Test the chamber connecting parts’ tightness effect. It’s |