Advanced Sterilization Cycles Laboratory Autoclave With 316L Chamber Double Door
Negotiable /Set
Min.Order:1 Set
Automatic Hinged Door Laboratory Autoclave With Customized Working Programs
Large Capacity Lab Sterilizer Biosafety Classified BSL3 And BSL4 Level
316L Chamber BSL3 / BSL4 Lab Scale Autoclave With Biological Seal Sliding Door
Vertical Sliding Door Laboratory Autoclaves With LCD Display Built - In Printer
Compact Single Door Laboratory Autoclaves , Autoclave Laboratory Equipment
Vertical Sliding Door Laboratory Autoclave With 17 Sterilization Programs
Advanced Sterilization Cycles Laboratory Autoclave With 316L Chamber Double Door
Description:
Autoclaves (also referred to as steam sterilizers) are designed to sterilize at temperatures between 212°F and 275°F (100°C and 135°C) through the use of steam. The Lab Series is particularly suitable for animal, life science, and medical research applications. Choose from a stainless steel or nickel-clad steel vessel construction in a variety of sizes and programmable control options for pre-vacuum or gravity operation.Key Features:
Chamber volume from 240 to 360 liters 5.7 inch Multi-color touch screen panel Keypad control panel on second door of two door autoclaves Stores the last 150 cycles in built-in memory Multiple access levels and user passwords to control access/operation of the autoclave Diagnostic In/Out test (enables technician to check each system component separately) Sterilization Temperature range 105°C to 135°C Filter replacement notifications Double door pass-through autoclave Autoclave chamber is made of AISI316L , piping and fittings are made from 304 stainless steel User friendly Touch Screen HMIParameters:
Model |
Chamber Size |
Overall Size |
Steam |
Water |
Power |
W*H*D mm |
W*H*D mm |
Kg/cycle |
Kg/cycle |
KVA |
|
MDL-0.24 |
600*600*670 |
1500*1800*1010 |
20 |
230 |
2 |
MDL-0.36 |
600*600*1000 |
1500*1800*1340 |
25 |
240 |
2 |
Advanced Sterilization Cycles:
The \"equivalent kill effect\" F0 value is calculated during the heat-up phase of a sterilization cycle thereby reducing
total media exposure time. Sterilization exposure time begins when the slowest-to-heat load temperature sensor within the autoclave has reached a predetermined set temperature.
Streaming Steam Cycle (105°C):
The streaming cycle is most commonly used for melting agar in Petri dishes. It is a low temperature sanitation cycle set at 105°C. Steam is allowed to enter the chamber and the fast exhaust valve is opened to allow steam to stream over the contents of the unit.
Applications:
These sterilizers are special designed for the sterilization of solid and porous biological products in biosafety laboratories like filters, sealing gaskets, empty containers, textiles and clothing, rubber stoppers, machine and system components.
Safe And Reliable Manufacturer:
In research institutes, universities and biosafety laboratories people work with highly sensitive laboratory materials requiring extremely responsible handling. Safety and reliability are vital factors in laboratory reprocessing. Medpharm is familiar with the demands running a laboratory poses and has been providing state-of-the-art solutions used in laboratories, pharmaceutical companies, biotech companies, universities and hospitals.