Double Door Hospital Steam Sterilizers With Full Jacket SS304 Chamber
Negotiable /Set
Min.Order:1 Set
Non - proprietary Parts Veterinary Autoclave With Independent Recording
Saturated Steam Double Door Autoclave With Safety Chamber Door System
Multiple Sterilization Cycles 120 Liter Double Door Laboratory Autoclave
1500 Liter Large Capacity Horizontal Autoclave With Stainless Steel Trolley
SS316 Chamber Horizontal Autoclave With Sterilizing Rubber Plugs Aluminum Caps
Safety Motorized Hinge Door Cgmp Regulations Horizontal Steam Autoclave Sterilizer
Double Door Hospital Sterilizer With Full Jacket SS304 Chamber
Description:
The double door Hospital sterilizer is compliant with CSSD standards as well as all other
additional and relevant guidelines.
This particular device features vertical sliding glass doors.
A highly compact and very efficient machine, this device is useful in hospitals for the
sterilization of rubber goods, textiles, glassware, containers and various instruments.
GENERAL SPECIFICATIONS:
• Material of Vessel, Jacket and Generator : AISI 304
• Exterior body : AISI 304
• stainless steel trolley for easy transporting
STANDARD PROGRAMS:
• 121 ºC Rubber
• 125 ºC Rubber
• 134 ºC Instrument
• 134 ºC Textile
• Bowie-Dick Test
• Leakage test
• Optional programs
CONTROL UNIT:
• 5.7\" colour touchscreen display
• Full automatic with microprocessor
Main Parameters:
Model |
Chamber Size |
Overall Size |
Net Weight |
Steam |
Water |
Power |
W*H*D mm |
W*H*D mm |
Kg |
Kg/cycle |
Kg/cycle |
KVA |
|
MD-0.30V |
600*600*840 |
1200*2000*1180 |
850 |
22 |
235 |
2 |
MD-0.36V |
600*600*1000 |
1200*2000*1340 |
900 |
25 |
240 |
2 |
MD-0.45V |
600*600*1250 |
1200*2000*1590 |
980 |
27 |
250 |
2 |
MD-0.60V |
600*600*1670 |
1200*2000*2010 |
1100 |
30 |
260 |
3 |
Medpharm’s strong engineering capability allows for highly customized autoclave design.
Facilities with space layout limitations will benefit from custom narrow design autoclaves
which provide high capacity in a limited space. Narrow design autoclaves allow for more
autoclaves in a given space to ensure continued sterile processing in case of autoclave
downtime.
Uniform Heat DistributionFully jacketed chambers ensure uniform heat distribution to ensure consistent serialization
conditions for all loads in chamber. A chamber that is not fully jacketed may have cool spots
which can cause improper sterilization.
Stainless Steel PipingStainless steel piping and connectors are used to avoid corrosion which is necessary to
safeguard the integrity of the autoclave and prevent contamination of the sterilized loads
(either as chemical or particulate contamination).