Silicon Rubber Train Insulators Minimum Creepage Distance 1600mm
USD $48.00 118.00 - $48.00 118.00 /Set
Min.Order:1 Set
ECR Composite Core Solid Pultrusion Fiberglass Rod 5mm Torsion Strength 800Mpa
Pultrusion Fiberglass Epoxy Resin Rod For Tension Insulators IEC Standard
Green Acid Resistant Pultruded Fiberglass Rod ECR Glass Solid Core Rod
Reinforced Pultruded Fiberglass Rod , Polymeric Insulator Solid ECR Rod
66kV Electric Line Post Insulator IEC 61952 Cross Arm Type For Power Lines
Small Volume Cross - Arm Solid Core Post Insulators 35kV for Electrical Powerline
Silicon Rubber Train Insulators Minimum Creepage Distance 1600mm
Specifications:
Dimensions and Characteristics of 25kV composite railway insulators
Figure No. | Type | Rated Voltage | Tension Failing Load | Section Length | Insulating Length | Minimum Creepage | Full-Wave Impulse Withstand Voltage(Peak) | 1 Min dry Power Frequency Withstand Voltage | 1 Min Wet Power Frequency Withstand Voltage | Weight(for Reference) |
H | h | ≥ | ≥ | ≥ | ||||||
(KV) | (KN) | (mm) | (mm) | (mm) | KV | KV | KV | (kg) | ||
407 | FQDG-25/20-EY | 25 | 20 | 1450±20 | 718 | 1600 | 310 | 190 | 150 | 3.6 |
Description:
1, 25kV composite railway insulators are widely used in electrified railways.
2, Dead end fittings are up to the requirements from the clients, usually we use ball, socket, tongue, clevis for tension insulators with forged steel or cast steel.
The dimensions and coupling size can be exactly according to the specification requirements from the utilities.
3, The silicon rubber color of the insulators are also up to the requirements from the clients and all the silicon rubber materials past 5000 hours aging test silicon content test and hydrophobicity test.
4, ECR core rods are used in all the insulators, so we can guarantee a very good mechanical strength and anti-acid pollution performance for the insulators.
5, All our insulators were type tested and design tested in accordance with IEC61109, maximum RIV is 100µV when tested at 1MHz and10% over nominal line ground voltage for indicated system voltage.
Applications:
1, Used in electrified railways
Advantages:
This kind of products have the following characters and advantages:
1) The silicon rubber rain shed, designed according to the aerodynamics principle, use the whole-moulding method, to make sure the validity of total creepage distance under every climate and nasty conditions, as well as improved the pollution discharge of the insulators.
2) The fiber rod uses the ECR high-temperature and acid-proof material.
3) The end fitting connection adopts the zinc cover protection, supersonic monitor and coaxial constant compression controlled by computer, finished with good appearance and high quality.
Advantages:
1) composite insulator with competitive price and good quality.
2) Hop dip galvanized cast SAE1045 steel for metal fittings.
3) silicone rubber for sheds
Our services
1. We offer the best solution and products to fulfill the buyers' requirements .
2. We can arrange technicians to install the equipments and train your staff on site.
3, We also provide OEM services.
4. Anytime, we provide considerate technical consultation.
5. Prompt reply for your inquiry and feedback.