Red 20kV Polymer Suspension Insulators Minimum Creepage Distance 750mm
USD $5.00 25.00 - $5.00 25.00 /Set
Min.Order:1 Set
15kV Polymer Composite Suspension Insulator , ECR Core Rod Electric Line Insulators
ECR Pultruded Fiberglass Rod High Temperature Resistant For Polymeric Insulators
Polymeric Insulators Pultrusion Rod Fiber Glass ECR Tensile Strength 1690Mpa
Polishing Pultruded Fiberglass Rod , Polymer Insulator Epoxy Resin FRP Rod
130mm Epoxy Resin Pultruded Rod Green Polishing For Polymer Insulators
Pultruded Fiberglass Composite Insulator Rod High Acid Resistance
Red 20kV Polymer Suspension Insulators Minimum Creepage Distance 750mm
Specifications:
Dimensions and Characteristics of 20kV composite Suspension Insulator
Figure. No | Model | Rated Voltage | Specified Mechanical Load | Coupling Size | Section Length |
Insulating length |
Minimum Creepage | Full-Wave Impulse Withstand Voltage (Peak) |
1 Min Wet Power Frequency Withstand Voltage |
Weight (for Reference) |
kV |
kN |
H mm |
h mm |
L mm |
≥ kV |
≥ kV |
kg |
|||
1.13-1 | FXBW-20/70-WT | 20 | 70 | 16 | 416±10 | 239 | 750 | 150 | 90 | 1.8 |
1.13-2 | FXBW-24/70-WT | 24 | 70 | 16 | 477±10 | 239 | 900 | 150 | 90 | 1.95 |
Description:
1, 20kV tension suspension insulators are widely used in overhead transmission lines and substations
2, Dead end fittings are up to the requirements from the clients, usually we use ball, socket, tongue, clevis for tension insulators with forged steel or cast steel. The dimensions and coupling size can be exactly according to the specification requirements from the utilities.
3, The silicon rubber color of the insulators are also up to the requirements from the clients and all the silicon rubber materials past 5000 hours aging test silicon content test and hydrophobicity test.
4, ECR core rods are used in all the insulators, so we can guarantee a very good mechanical strength and anti-acid pollution performance for the insulators.
5, All our insulators were type tested and design tested in accordance with IEC61109, maximum RIV is 100µV when tested at 1MHz and10% over nominal line ground voltage for indicated system voltage.
6, All the 20kV tension suspension insulators are without corona ring
Applications:
1, 20kV overhead transmission power lines.
2, 20kV Substations
3, 20kV distribution lines
Advantages:
This kind of products have the following characters and advantages:
1) The silicon rubber rain shed, designed according to the aerodynamics principle, use the whole-moulding method, to make sure the validity of total creepage distance under every climate and nasty conditions, as well as improved the pollution discharge of the insulators.
2) The fiber rod uses the ECR high-temperature and acid-proof material.
3) The end fitting connection adopts the zinc cover protection, supersonic monitor and coaxial constant compression controlled by computer, finished with good appearance and high quality.
Our services
1. We offer the best solution and products to fulfill the buyers' requirements .
2. We can arrange technicians to install the equipments and train your staff on site.
3, We also provide OEM services.
4. Anytime, we provide considerate technical consultation.
5. Prompt reply for your inquiry and feedback.