EHV AC Transmission Line Insulator Polymer 110 kV High Flexibility
USD $ 6.00 - $75.00 /Piece
Min.Order:1 Piece
66kv Substation Composite Suspension Insulator Long Rod With One Corona Ring
Silicone Rubber Suspension 33kv Insulator Light Weight For Distribution Lines
Red 20kV Polymer Suspension Insulators Minimum Creepage Distance 750mm
15kV Polymer Composite Suspension Insulator , ECR Core Rod Electric Line Insulators
ECR Pultruded Fiberglass Rod High Temperature Resistant For Polymeric Insulators
Polymeric Insulators Pultrusion Rod Fiber Glass ECR Tensile Strength 1690Mpa
EHV AC Transmission Line Insulator Polymer 110 kV High Flexibility
Specification
Dimensions and Characteristics of 110kV composite suspension insulator
Figure. No | Model | Rated Voltage | Specified Mechanical Load | Section Length | Insulating length | Minimum Creepage | Full-Wave Impulse Withstand Voltage (Peak) | 1 Min Wet Power Frequency Withstand Voltage | Weight (for Reference) |
kV | kN | H mm | h mm | L mm | ≥ kV | ≥ kV | kg |
||
1.10-2 | FXBW4-110/70-B | 110 | 70 | 1240±15 | 1025 | 3900 | 550 | 230 | 5.2 |
1.10-1 | FXBW4-110/70-C | 110 | 70 | 1440±15 | 1225 | 3800 | 550 | 230 | 5.8 |
1.10-2 | FXBW4-110/70-D | 110 | 70 | 1440±15 | 1225 | 4500 | 550 | 230 | 6.0 |
1.10-1 | FXBW4-110/100-A | 110 | 100 | 1240±15 | 1020 | 3300 | 550 | 230 | 5.1 |
1.10-2 | FXBW4-110/100-B | 110 | 100 | 1240±15 | 1020 | 3900 | 550 | 230 | 5.2 |
1.10-1 | FXBW4-110/100-C | 110 | 100 | 1440±15 | 1220 | 3800 | 550 | 230 | 5.8 |
1.10-1 | FXBW-110/100 | 110 | 100 | 1380±15 | 1125 | 3700 | 550 | 230 | 7.2 |
1.10-1 | FXBW-110/160 | 110 | 160 | 1380±15 | 1115 | 3700 | 550 | 230 | 8.7 |
Description:
1, 110kV tension suspension insulators are widely used in overhead transmission lines and substations
2, Dead end fittings are up to the requirements from the clients, usually we use ball, socket, tongue, clevis for tension insulators with forged steel or cast steel. The dimensions and coupling size can be exactly according to the specification requirements from the utilities.
3, The silicon rubber color of the insulators are also up to the requirements from the clients and all the silicon rubber materials past 5000 hours aging test silicon content test and hydrophobicity test.
4, ECR core rods are used in all the insulators, so we can guarantee a very good mechanical strength and anti-acid pollution performance for the insulators.
5, All our insulators were type tested and design tested in accordance with IEC61109, maximum RIV is 100µV when tested at 1MHz and10% over nominal line ground voltage for indicated system voltage.
6, All the 110kV tension suspension insulators are with one corona ring
Applications:
1, 110kV EHV AC overhead transmission power lines.
2, 110kV EHV AC substations
Competitive Advantage:
1, Very good anti-pollution performance, no need to wash the insulators after the installation in lines.
2, Very convenient installation because of its light weight and one whole piece compared with glass insulators and ceramic insulators.
3, Excellent hydrophobicity characteristics can help to void flashover and guarantee the insulators with very good electric performance.