High Voltage Railway Insulators Polymeric IEC61109 Light Weight
USD $48.00 168.00 - $48.00 168.00 /Set
Min.Order:1 Set
Safety Silicone Rubber Insulator For Railway High Vandal Resistance
Silicon Rubber Train Insulators Minimum Creepage Distance 1600mm
ECR Composite Core Solid Pultrusion Fiberglass Rod 5mm Torsion Strength 800Mpa
Pultrusion Fiberglass Epoxy Resin Rod For Tension Insulators IEC Standard
Green Acid Resistant Pultruded Fiberglass Rod ECR Glass Solid Core Rod
Reinforced Pultruded Fiberglass Rod , Polymeric Insulator Solid ECR Rod
High Voltage Railway Insulators Polymeric IEC61109 Light Weight
Specifications:
Dimensions and Characteristics of 25kV composite railway insulators
Figure No. | Type | Rated Voltage | Tension Failing Load | Section Length | Insulating Length | Shed diameterS | Shed Spacing | Minimum Creepage | Full-Wave Impulse Withstand Voltage(Peak) | Weight |
H | h1/h2 | D | B | ≥ | ||||||
(KV) | (KN) | (mm) | (mm) | (mm) | (mm) | (mm) | KV | (kg) | ||
3231 | FQXS-25/70,100,120-HH | 25 | 70,100,120 | 790±20 | 500/60 | 145 | 78 | 1200/145 | 270/50 | 3.2 |
FQXSJ-25/70,100,120-HH | 25 | 70,100,120 | 840±20 | 550/60 | 145 | 78 | 1400/145 | 290/50 | 3.2 | |
FQXSG-25/70,100,120-HH | 25 | 70,100,120 | 890±20 | 600/60 | 145 | 78 | 1600/145 | 310/50 | 3.4 | |
3232 | FQXS-25/160-HH | 25 | 160 | 840±20 | 500/56 | 100 | 35 | 1200/145 | 270/50 | 4.6 |
FQXSJ-25/160-HH | 25 | 160 | 890±20 | 550/56 | 100 | 35 | 1400/145 | 290/50 | 4.8 | |
FQXSG-25/160-HH | 25 | 160 | 940±20 | 600/56 | 100 | 35 | 1600/145 | 310/50 | 5.0 | |
3232 | FQXS-25/200-HH | 25 | 200 | 840±20 | 500/56 | 100 | 35 | 1200/145 | 270/50 | 4.6 |
FQXSJ-25/200-QH | 25 | 200 | 890±20 | 550/56 | 100 | 35 | 1400/145 | 290/50 | 4.8 | |
FQXSG-25/200-HH | 25 | 200 | 940±20 | 600/56 | 100 | 35 | 1600/145 | 310/50 | 5.0 |
Description:
1, 25kV composite railway insulators are widely used in electrified railways.
2, Dead end fittings are up to the requirements from the clients, usually we use ball, socket, tongue, clevis for tension insulators with forged steel or cast steel.
The dimensions and coupling size can be exactly according to the specification requirements from the utilities.
3, The silicon rubber color of the insulators are also up to the requirements from the clients and all the silicon rubber materials past 5000 hours aging test silicon content test and hydrophobicity test.
4, ECR core rods are used in all the insulators, so we can guarantee a very good mechanical strength and anti-acid pollution performance for the insulators.
5, All our insulators were type tested and design tested in accordance with IEC61109, maximum RIV is 100µV when tested at 1MHz and10% over nominal line ground voltage for indicated system voltage.
Applications:
1, Used in electrified railways
Advantage No. One