Light Weight Composite Polymer Insulator , 66kv Silicon Rubber Substation Insulators

Light Weight Composite Polymer Insulator , 66kv Silicon Rubber Substation Insulators

USD $ 6.00 - $75.00 /Piece

Min.Order:1 Piece

Supply Ability:
0 Piece / Pieces per Month
Payment Terms:
T/T L/C D/P D/A
Delivery Detail:
7 days

Quick Details View All >

Brand Name:
Changgong
Place of Origin:
China
Model Number:
FXBW-66/100-940 to FXBW-66/120-1066-YS

Jiangsu Xiangyuan Electric Equipment Co., Ltd.

Business Type: Trading Company
Main Products:

Product Details

Delivery Time:Start from 10 days
Certification:ISO 66kV type test report and 66kV design test report

Light Weight Composite Polymer Insulator , 66kv Silicon Rubber Substation Insulators

Specifications:

Dimensions and Characteristics of 66kV(63kV) composite polymer insulator

Figure. No Model Rated Voltage Specified Mechanical Load Coupling Size Section Length Minimum Creepage Full-Wave Impulse Withstand Voltage (Peak)

1 Min Wet Power Frequency Withstand Voltage

Weight (for Reference)
   

kV

kN

 

H

mm

L

mm

kV

kV

kg

1.11-1 FXBW-66/100-940 66 100 16 940±15 2200 410 185 3.7
1.11-1 FXBW-66/120-940 66 120 16 940±15 2200 410 185 3.7
1.11-1 FXBW-66/100-870-A 66 100 16 870±15 1920 410 185 3.3
1.11-1 FXBW-66/120-870-A 66 120 16 870±15 1920 410 185 3.3
1.11-2 FXBW-66/100-870-B 66 100 16 870±15 2000 410 185 3.6
1.11-2 FXBW-66/120-870-B 66 120 16 870±15 2000 410 185 3.6
1.11-3 FXBW-66/120-1066-YS 66 80 16 1066±15 2800 410 185 4.5

Description:

1, 66kV(63kV)composite polymer insulator are widely used in 66kV(63kV) overhead transmission lines and substations.

2, Dead end fittings are up to the requirements from the clients, usually we use ball, socket, tongue, clevis for suspension insulators with forged steel or cast steel. The dimensions and coupling size can be exactly according to the specification requirements from the utilities.

3, The silicon rubber color of the insulators are also up to the requirements from the clients and all the silicon rubber materials past 5000 hours aging test silicon content test and hydrophobicity test.

4, ECR core rods are used in all the insulators, so we can guarantee a very good mechanical strength and anti-acid pollution performance for the insulators.

5, All our insulators were type tested and design tested in accordance with IEC61109, maximum RIV is 100µV when tested at 1MHz and10% over nominal line ground voltage for indicated system voltage.

Applications:

1, 66kV(63kV) overhead transmission power lines.

2, 66kV(63kV)substations

Competitive Advantage:

<

Contact Supplier

Mr. Warren sale Manager Chat Now
Telephone
86-755-26927358
Mobile
86-75526927358
Fax
86-755-26927358
Skype
warren.zhou0517
Address
Group 3, Zhennan Village, Chaiwan Town, Rugao City Shaoxing,Zhejiang

New Products

Recommended Products

View More View Less

Find Similar Products By Category

The advantages of polymer/composite insulators over ceramic/porcelain insulators
General comparison
Factor Ceramic/porcelain insulators Polymer/composite insulators
Weight

Heavy weight- For example

400kV - about 140kgs

90% lighter than them but with same mechanical strength

400kV -- Around 15kgs

Fragility Highly fragility to shock and vibration No fragility to shock and vibration
Packing and transportation Risky and very costly Easy and economical
Installation Risky expensive and more labor required Very easy and economical
Handling Difficult Easy
Maintenance cost Very expensive Low
Vandalism More susceptible Highly resistant
Breakages and secondary damage Highly fragile- 10-15% breakages are reported during transportation storage and installation Flexible and therefore highly resistant to breakages
Technical comparison