[Product Description]
SCU - Support Control Unit
Each RBS6201 1 SCU.
SCU fan control, support for EC-bus connect SAU and provides the -48V DC power supply
GSM wireless base station for Ericsson BTS RBS6201 SCU0201 BGM 136 1006/2 R2A in stock.
Ericsson RBS6201 is an indoor macro base station, we have all version in this store.
If you need more information, pls directly contact us through online tool or other way you prefer to.
[Product code]
BFM 901 290
KDU 137 569/1
KFE 101 1157/4
BMG 980 336/4
KFE 101 1162/2
KRF 102 296/1
KRY 901 119/1
KRC 161 263/1
ZHY 601 17/1
BGM 136 1006/2
BGK 901 18/2
RBS6201 |
BFM 901 290 |
BFM 901 290 R6A |
Cabinet |
DUG 20 01 |
KDU 137 569/1 |
KDU 137 569/1 R2B KDU 137 569/1 R2D KDU 137 569/1 R3C KDU 137 569/1 R3D KDU 127 161/2 R4C KDU 127 161/2 R4E |
RBS6201 The main control unit,Can also be used for RBS6601 DUG 20 01+SUP6601=MU,Supports up to 12TRX. |
PCF 02 03 |
KFE 101 1157/4 |
KFE 101 1157/4 R1F KFE 101 1157/4 R1H |
The power supply connection filtering, connected to an external -48V DC to RBS cabinet. |
PDU 02 01 |
BMG 980 336/4 |
BMG 980 336/4 R2C BMG 980 336/4 R2G BMG 980 336/4 R2H |
PDU (equivalent to IDM) assigned to other units -48V. |
PFU 02 01 |
KFE 101 1162/2 |
KFE 101 1162/2 R1D |
Filter in RBS, -48V, DC system voltage stability. |
RUS 01 B0 |
KRF 102 296/1 |
KRF 102 296/1 R1B |
900M carrier module,Supports up to 4 carrier. |
RUS 01 B3 |
KRY 901 119/1 |
KRY 901 119/1 R1E |
1800M carrier module,Supports up to 4 carrier. |
RUS 02 B0 |
KRC 161 263/1 |
KRC 161 263/1 R1K |
900M carrier frequency module, supports up to 8 carrier. |
SAU 01 01 |
ZHY 601 17/1 |
ZHY 601 17/1 R1D |
Installed in the DM box, expand external alarm to 32 Road. |
SCU 02 01 |
BGM 136 1006/2 |
BGM 136 1006/2 R2A |
1.To provide external alarm interface; 2.To the fan power supply; 3.To control the fan to adjust the temperature in the cabinet Voltage alarm; 4.PMU monitoring. |
SHU 02 01 |
BGK 901 18/2 |
BGK 901 18/2 R1B BGK 901 18/2 R1D |
The monitoring information of each unit in the cabinet of centralized forwarding to the main control DUG, connected to an external unit such as PDU, SCU to DU. |