Portable powerful professional Q switch Nd Yag laser tattoo removal system 1064nm & 532nm for salon beauty equipment
USD $1 - $2 /Piece
Min.Order:1 Piece
Guangzhou Realtop Beauty Equipment Co., Ltd.
Portable powerful professional Q switch Nd Yag laser tattoo removal
system 1064nm & 532nm for salon beauty equipment
Theory:
ND: YAG Laser Cosmetic System introduces gem_adjusting Q switch, which uses high energy by instant emission of laser beam to crush and remove the pigment effectively in the pathologically changed tissues. That is an explosion led by laser beam: the laser beam at the fixed wavelength enabled by the accumulated high energy can reach the pathologically changed tissues through epidermis in a very short time (only 6 ns) to instantly crush the respective color base, then the corresponding pigment group gets swollen and outburst at last due to high energy, and part of the pigment group springs out of the human body (at shallow epidermis), and the rest (at basis tissues) pigment group will become very small particle before swallowed by the human cell which will be finally discharged out of the human body through lymphatic system circulation. The pigment of the pathological tissues will fade in color till it vanishes. And the surrounding normal tissues will not be ruined since they will not absorb the laser at that fixed wavelength .
Application:
The system gem_adjusting Q switch can effectively cure the mixed pigments by pigment precipitation of extraneous source with pathological pigment change of endogenous source, inclusive of erroneous dark eyebrow_embroidery, lip_embroidery, lip_soak, eye line_embroidery, lip_line, tattoo (inclusive of tattoo by extraneous wounds), pigment precipitation by sensitive source, freckle on female's face (male's), coffee spot, old age spot, black mole, and birthmark in black, blue, purple, brown, red and etc. Treatment course for different illness case as follows:
(1)Treatment for tattoo in eyebrow
Customer could not open eyes during treatment, operator should adjust energy according to depth of tattoo color, hold the handle and move it to treatment area slowly to make customer feel acceptable in mentally. Right now, the speed of flash could be set 3HZ, keep head of the handle a two_finger distance to treatment area, start treatment from head of eyebrow to end of eyebrow. It is needed to treat again in 5_10 minutes if the color of tattoo re_appear.
(2)Remove eye line
The speed of flashes could be set 4_5HZ,adjust the energy of light to minimum energy, keep a one_finger distance between head of handle and treatment area. Operator should strictly protect customers’ eyes with panel for eyelid or medical pledget (panel for eyelid)of 1cm depth.
Treatment should be started from down eye line, customer should deeply close eyes and keep eyeball up_sight inside. Operator should press the pledget (panel for eyelid) with forefinger and push up eyelid, peel down eyelid with middle finger to bare the eye line, treat it with flashes of 4_5Hz. Then, treat up eye line. Also customer should close eyes and keep eyeball down_sight inside. Operator should press the pledget (panel for eyelid) with middle finger and push eyelid down, push eyelid up with forefinger to bare the eye line, treat it with flashes of 4_5Hz.
(3)Remove lip line
The speed of flashes could be set 5Hz,keep a 3/4 finger distance between head of handle and treatment area. It is better to remove black, coffee, deep, red and brown lip line with 1064nm head at first time and then, treat again with 532 nm head.
Notice: All tattoos in lip should be treated in 6 months after making. OR removal treatment will fail. It should have 45-60 days interval to continue next treatment until remove all.
(4)Remove tattoo
The speed of flashes could be set 3Hz/5Hz.It is better to use high energy for treatment until treatment area seeps a little blood. It should have 45_90 days interval to continue next treatment until remove all.
(5)Remove spot and nevus
The speed of flashes could be set 3Hz/5Hz.Keep 3_4 fingers distance between head of handle and treatment area. It is better to use high energy for treatment until treatment area seeps a little blood. It is advised to use 1064 nm head for normal spot and nevus treatment, but for deep color spot and nevus, it is better to use 532nm head for treatment. It should have a 15-30days interval to continue next treatment until remove all.
(6)Remove birthmark
The speed of flashes could be set 3Hz/5Hz.It is better to use high energy for treatment until treatment area seeps a little blood. It is advised to use 1064nm head for birthmark treatment, but for red and deep color birthmark, it is better to use 532nm head for treatment. It should have 45-90 days interval to continue
YAG laser tattoo removal machine features:
1.Portable YAG laser tehnique
2.without anesthesia
3.without damaging normal skin
4.easy maintenance
5.without damaging normal skin
6. 1064nm can get rid of eye line, eyebrow line, lip line, tattoo, speckle (black, blue, etc.)
532nm can get rid of eyebrow line, eye line, lip line, tattoo, speckle, titian nevus (red, brown, etc.) and capillary vessel dilatation
7. The highest configuration in small Q-switch ND:YAG lasers
8. Color touch screen with independent treatment functions, much easier operation
9. Plug-and-play handle, simple installation
10. No side effect, no scar, no down time
Laser treatment projects operating practices
1064nm: regulation of energy to start with a laser gun head alignment operation portion emitting (the distance between the gun and the skin of approximately 10cm), one portion followed by a portion emitting until you see can be micro oozing (smear repair factor repair).
532nm:regulation of energy to start with a laser gun head alignment operation portion emitting (the distance between the gun and the skin of approximately 10cm), one portion followed by a portion emitting until you see can be micro oozing (smear repair factor repair).
BD-LS(Black doll):Clean skin, daub medical carbon on the face (wait for 8-10 minutes).let it absorbed into the pores. until the medical carbon become the smoke Disappear . Then clean the face can be.
Note:1064nm,532nm treatment 48 hours can not in contact with water, the Black doll treatment 24 hours can’t in contact hot water.
Specification
1.Treatment head : 1064nm & 532nm&Black doll
2.Laser type: sapphire ruby switch Q/KTP/YAG laser instrument
3.Energy: 1000mj
4.Indication light: infrared ray indication light
5.Width of pulse: 10ns
6.Frequency: 1-6 HZ
7.Spot diameter: 1-10mm
8.Cooling manner: wind water
9.Input power: AC 220V(110V)/ 15A 50HZ(60HZ)
10. red aim beam can be proper place.
Effect:
Free training for operation of the machine in our company, which provided by our specialized training department.
On-line services, for example, technical consultancies provided by our skilled technique group concerning any question of the laser machine, and after-sale maintenance and more.
OEM/ODM services are available. We have our own developing and design department and manufacturing line, which ensure your required beauty machine.
Quality guarantee:One year
Our After-sales Service:
1.1 year warranty with professional support
2.Within 1 year, Supply spare parts for free if the machine has quality problem
Dear,if you have any question ,welcome to contact us !!