Wholesale price 1064nm/532nm/black doll q switched nd:yag laser skin whitening eliminates the age pigment tatoo removal machine
USD $1 - $2 /Piece
Min.Order:1 Piece
Guangzhou Realtop Beauty Equipment Co., Ltd.
Wholesale price 1064nm/532nm/black doll q switched nd:yag laser skin
whitening eliminates the age pigment tatoo removal machine
Theory:
The Q-switched ND: YAG laser delivers light of specific wavelengths with high energy which are absorbed by the pigment in the tattoo and result in a shockwave. The shockwave shatters the pigment particles, releasing them from their encapsulation and breaking them into fragments small enough for removal by the body. These tiny particles are then eliminated by the body. Since this specific wavelength can only be absorbed by pigment particles, no injury to skin and normal tissues will occur.
Application:
The system gem-adjusting Q switch can effectively cure the mixed pigments by pigment precipitation of extraneous source with pathological pigment change of endogenous source, inclusive of erroneous dark eyebrow embroidery, lip embroidery,lip-soak,eye line-embroidery, lip-line, tattoo (inclusive of tattoo by extraneous wounds), pigment precipitation by sensitive source, freckle on female's face (male's), coffee spot, old age spot, black mole, and birthmark in black, blue, purple, brown, red and etc. Treatment course for different illness case as follows:
(1)Treatment for tattoo in eyebrow
Customer could not open eyes during treatment, operator should adjust energy according to depth of tattoo color, hold the handle and move it to treatment area slowly to make customer feel acceptable in mentally. Right now, the speed of flash could be set 3HZ, keep head of the handle a two-finger distance to treatment area, start treatment from head of eyebrow to end of eyebrow. It is needed to treat again in 5-10 minutes if the color of tattoo re-appear.
(2)Remove eye line
The speed of flashes could be set 4-5HZ,adjust the energy of light to minimum energy, keep a one-finger distance between head of handle and treatment area. Operator should strictly protect customers’ eyes with panel for eyelid or medical pledget (panel for eyelid)of 1cm depth.Treatment should be started from down eye line, customer should deeply close eyes and keep eyeball up-sight inside. Operator should press the pledget (panel for eyelid) with forefinger and push up eyelid, peel down eyelid with middle finger to bare the eye line, treat it with flashes of 4-5Hz. Then, treat up eye line. Also customer should close eyes and keep eyeball down-sight inside. Operator should press the pledget (panel for eyelid) with middle finger and push eyelid down, push eyelid up with forefinger to bare the eye line, treat it with flashes of 4-5Hz.
(3)Remove lip line
The speed of flashes could be set 5Hz,keep a 3/4 finger distance between head of handle and treatment area. It is better to remove black, coffee, deep, red and brown lip line with 1064nm head at first time and then, treat again with 532 nm head.
Notice: All tattoos in lip should be treated in 6 months after making. OR removal treatment will fail. It should have 45-60 days interval to continue next treatment until remove all.
(4)Remove tattoo
The speed of flashes could be set 3Hz/5Hz.It is better to use high energy for treatment until treatment area seeps a little blood. It should have 45-90 days interval to continue next treatment until remove all.
(5)Remove spot and nevus
The speed of flashes could be set 3Hz/5Hz.Keep 3-4 fingers distance between head of handle and treatment area. It is better to use high energy for treatment until treatment area seeps a little blood. It is advised to use 1064 nm head for normal spot and nevus treatment, but for deep color spot and nevus, it is better to use 532nm head for treatment. It should have a 15-30days interval to continue next treatment until remove all.
(6)Remove birthmark
The speed of flashes could be set 3Hz/5Hz.It is better to use high energy for treatment until treatment area seeps a little blood.It is advised to use 1064nm head for birthmark treatment, but for red and deep color birthmark, it is better to use 532nm head for treatment. It should have 45-90 days interval to continue
Parameter:
Technical Standard | Light Source | Q-switches Nd: YAG Laser |
Pulse Energy | 0 - 800MJ/cm2 | |
Wave Length | 1064nm & 532nm | |
Power Supply | AC220V/50Hz or AC110V/60Hz | |
Pulse Width | 0 - 6ns | |
Facular Diameter | 1mm - 10mm | |
Repeat Frequency | 1Hz - 6Hz | |
Cooling System | Winding Cooling Water Cooling Semi-conductor Cooling System | |
Treatment Area | 1mm2- 10mm2 | |
Instrument Standard | Outer Dimension | 43.5×38×41.5cm3 |
Inner Dimension | 42×25×36cm3 | |
Gross Weight | 20KG | |
Net Weight | 15KG | |
Working Condition | Conduct Temperature | 5 - 25 |
Relative Humidity | ≤70% | |
Barometric | 860hPa - 1060hPa | |
Shipping Store | Temperature | 20 - 55 |
Relative Humidity | ≤90% | |
Barometric | 500hPa - 1060hPa | |
Working Mode | The working time should be controlled less than 40 minute every time and then stop for 20 minutes. |
Operation Picture:
Free training: for operation of the machine in our company, which provided by our specialized training department.
On-line services: for example, technical consultancies provided by our skilled technique group concerning any question of the laser machine, and after-sale maintenance and more.
OEM/ODM services: are available. We have our own developing and design department and manufacturing line, which ensure your required beauty machine.
Quality guarantee:One year
Our After-sales Service:
1.1 year warranty with professional support
2.Within 1 year, Supply spare parts for free if the machine has quality problem
Dear,if you have any question ,welcome to contact us !!