201W 15V 13A ac/dc power suppies(S-201-15)
Negotiable /Piece
Min.Order:10 Pieces
Zhejiang Lierd Relays Enterprise Co., Ltd.
201W 15V 13A ac/dc power suppies(S-201-15)
Model | S-201-5 | S-201-7.5 | S-201-12 | S-201-13.5 | S-201-15 | S-201-24 | S-201-27 | S-201-48 |
DC output voltage | 5V | 7.5V | 12V | 13.5V | 15V | 24V | 27V | 48V |
Output voltage range(Note:2) | ±2% | ±2% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% |
Rated output current | 40A | 26.5A | 16.5A | 14.7A | 13A | 8.3A | 7.4A | 4.2A |
Output current range | 0-40A | 0-26.5A | 0-16.5A | 0-14.7A | 0-13A | 0-8.3A | 0-7.4A | 0-4.2A |
Wave and noise(Note:3) | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 240mVp-p |
Inlet stability(Note:4) | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load stability(Note:5) | ±1% | ±1% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
DC output power | 200W | 198.75W | 198W | 198.45W | 198W | 199.2W | 199.8W | 201.6W |
Efficiency | 74% | 79% | 80% | 80% | 81% | 83% | 83% | 84% |
Adjustable range for DC voltage | 4.5~5.6V | 6~9V | 10~13.2V | 12~15V | 13.5~18V | 20~26.4V | 26~32V | 41~56V |
Input current | 3.6A/115V 1.8A/230V | |||||||
AC inrush current | 25A/115V50A/230V | |||||||
Leakage current | <3.5mA/240VAC | |||||||
Overload protection | 105%~150% Type: pulsing hiccup shutdown Reset: auto recovery | |||||||
High-temperature protection | ERH3≥90°c output shutdown | |||||||
Temperature coefficient | ±0.03%/°c(0~50°c) | |||||||
Setup, rise , hold up time | 200ms,100ms, 20ms | |||||||
Vibration | 10~500Hz, 2G 10min,/1cycle, Period for 60min, Each axes | |||||||
Withstand voltage | Input and output internal: 1.5KvAC, Input and enclosure:1.5KvAC, Output and enclosure:0.5KvAC | |||||||
Working temperature and humidity | -10°c~+60°c(Refer to output derating curve), 20%~90%RH | |||||||
Weight | 0.9Kgs | |||||||
Safety standards | Design ferer to UL 1950 | |||||||
EMC standards | Design refer to FCC Part15 J Part15J classA | |||||||
Note: 1. The testing condition for the parameter above is: 230VAC input, rated load, 25°c 70% RH.Temperatuer. 2. Error: include the setting error, line stability and load stability.(Note:5). 3.Wave test: adopting "A12" double wire for 20 MHz, and 0.1 UF&47UF capacitor short-circuit for interrupting. 4. Inlet voltage stability test: wht is overload, the lowest voltage of inlet is up to the highest voltage. 5. Load stability test: The load is from 0% to 100% |